Panasonic AW-HE42 IP Control Specifications - Page 213
Registered number of update notifications
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 213 highlights
HD Integrated Camera Interface Specifications ② Update notification receive end step To close the application of the client, the update notification receive end step must be taken without fail. Example) When reception is to be ended with "192.168.0.10" used as the IP address of the camera http://192.168.0.10/cgi-bin/event?connect=stop&my_port=31004&uid=0 ※my_port ... Number of the TCP port on the terminal (fixed at 31004) Given below is the sequence which is followed when receiving the update notifications is to be ended. 【Update notification receive end sequence】 The update notification receive end command is sent from the terminal which has received the update notifications. "204 No Content" is returned from the camera which received the command. PC1 (Client) Camera http://192.168.0.10/cgi-bin/event?connect=stop&my_port=31004&uid=0 204 No Content The receiving of the update notifications at PC1 is ended Fig.4-2 Update notification receive end sequence 4.1.2. Registered number of update notifications You can query the number of external devices (RP remote controller etc.) connected to the camera with the following command. The number of connected device increases with the procedure to start receiving update notifications and decreases the procedure to start receiving update notifications. The number of connected device also decreases when it can not communicate with the device. Request Response /cgi-bin/man_session?command=get Event session:* (*: Registered number) © Panasonic Corporation 2020 All Rights Reserved. - 213 -