Panasonic AW-HE42 IP Control Specifications - Page 137
Pedestal setting
![]() |
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
HD Integrated Camera 3.2.14. Pedestal setting Interface Specifications These commands control the pedestal of the camera and enable the current settings to be acquired. Command name Pedestal control command Category Control Table 3.2.14. Pedestal setting Command Data value Setting Remarks OTP:[Data] In the case of the AW-HE50/AW-HE60/AW-HE40/ AW-UE70/AW-HE42 000h -10 Setting (menu display value) = (Data value - 0x96) / 15 ~ ~ ~ ~ 096h 0 Disabled at the FullAuto setting (ER3 is returned). 12Ch +10 In the case of the AW-HE120/AW-HE130/AW-HR140 000h -150 Setting (menu display value) = (Data value - 0x96) 096h 0 ~ ~ ~ ~ Response OTP:[Data] Control OTD:[Data] 12Ch +150 In the case of the AW-HE50/AW-HE60/AW-HE40/ AW-UE70/AW-HE42 00h -10 Setting (menu display value) = (Data value - 0x96) / 3 ~ ~ ~ ~ 1Eh 0 Disabled at the FullAuto setting (ER3 is returned). 3Ch +10 In the case of the AW-HE120/AW-HE130/AW-HR140 00h -150 Setting (menu display value) = (Data value - 0x1E) x 5 1Eh 0 ~ ~ ~ ~ Pedestal query command Response OTD:[Data] Request QTP Response OTP:[Data] 3Ch +150 None In the case of the AW-HE50/AW-HE60/AW-HE40/ AW-UE70/AW-HE42 000h -10 Data value of response = (Setting x 15 + 0x96) 096h 0 ~ ~ ~ ~ 12Ch +10 In the case of the AW-HE120/AW-HE130/AW-HR140 000h -150 Data value of response = (Setting + 0x96) 096h 0 ~ ~ ~ ~ 12Ch +150 © Panasonic Corporation 2020 All Rights Reserved. - 137 -
![](/manual_guide/products/panasonic-awhe42-ip-control-specifications-f4b7fd2/137.png)