Sharp AR-BC260 ARBC260 Operation Manual - Page 65
Misfeed in the large capacity tray
View all Sharp AR-BC260 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
LARGE CAPACITY TRAY Misfeed in the large capacity tray When a misfeed occurs in the large capacity tray, remove the misfed paper, following the procedure below. 1 While holding the tray release lever, carefully slide the large capacity tray away from the main unit until it stops. 5 Push the large capacity tray towards the main unit and latch it into place. Gently push the large capacity tray back in until it stops. Release lever 2 Remove any misfed paper from the main unit and the large capacity tray. Upper right side cover If the misfed paper is stuck inside the machine and cannot be removed, open the side cover and then remove the misfed paper. (See "Misfeed in the transport area, fusing area, and exit area" on page 2-20.) 6 If misfed paper is not found in step 2, pull the tray out. 3 7 Remove the misfed paper. 3 Open the top cover. 4 Remove the misfed paper. Be sure not to tear the misfed paper during removal. After removing the misfed paper, close the top cover. 8 Gently push the tray back into place. The paper feed table automatically rises to the paper feed position. Make sure that the paper misfeed screen is cleared and the normal message screen appears. 3-17