Table 1-2., LCD Status Messages Optional, Causes, Corrective Actions, E1116 Memory
View all Dell PowerEdge R415 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Table 1-2. LCD Status Messages (Optional) Code E1000 E1114 E1116 E1119 E1210 E1211 Text Causes Corrective Actions Failsafe Check the system event voltage error. log for critical failure Contact events. support. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 181. Ambient Temp Ambient temperature has See "Troubleshooting exceeds a reached a point outside System Cooling allowed range. of the allowed range. Problems" on page 156. Memory Memory has exceeded Remove AC power to the disabled, temp allowable temperature and system for 10 seconds and above range. has been disabled to restart the system. Power cycle AC. prevent damage to the components. See "Troubleshooting System Cooling Problems" on page 156. If the problem persists, see "Getting Help" on page 181. Chipset # temp out of range. Check motherboard heatsinks. Chipset temperature reached a point outside the allowed range. See "Troubleshooting System Cooling Problems" on page 156. Motherboard CMOS battery is missing See "Troubleshooting the battery or the voltage is outside of System Battery" on failure. Check the allowable range. page 155. battery. RAID RAID battery is either Reseat the RAID battery Controller missing, bad, or unable to connector. See "RAID battery recharge due to thermal Battery (Optional)" on failure. Check issues. page 119, and battery. "Troubleshooting System Cooling Problems" on page 156. About Your System 25