Dell PowerEdge R415 Hardware Owner's Manual - Page 31
PCI system, error on Bus, error on Slot, Review &, clear SEL., Unknown error., Review & clear
View all Dell PowerEdge R415 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code E1712 E1714 E1715 Text Causes Corrective Actions PCI system error on Bus ## Device ## Function ## The system BIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##. Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 165. PCI system error on Slot #. Review & clear SEL. The system BIOS reported Remove and reseat the a PCI system error on a expansion-card riser that component that resides in provides the specified the specified slot. slot. See "Expansion Card and Expansion-Card Riser" on page 99. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 181. Unknown error. The system BIOS has Review & clear determined there has SEL. been an error in the system, but is unable to determine its origin. Check the SEL for more information and then clear the SEL. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 181. Fatal I/O Error. Review & clear SEL. The system BIOS Check the SEL for more determined there has been information, and then a fatal error in the system. clear the SEL. Remove AC power to the system for 10 seconds, and restart the system. If the problem persists, see "Getting Help" on page 181. About Your System 31