Table 1-3. System Messages (continued) Message Causes Corrective Actions Unsupported memory configuration. DIMM mismatch across slots detected: x,x,... Invalid memory configuration. Memory modules are mismatched in the specified slots. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 122. Warning: A fatal A fatal system error occurred Check the SEL for error has caused and caused the system to information that was logged system reset! reboot. during the error. See the Please check the applicable troubleshooting system event log! section in "Troubleshooting System Memory" on page 157 for any faulty components specified in the SEL. Warning! Power required exceeds PSU wattage. Check PSU and system configuration. Warning! Performance degraded. CPU and memory set to minimum frequencies to meet PSU wattage. System will reboot. The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If low wattage power supplies are installed, replace them with High Output power supplies to use the components. See "Power Supplies" on page 95. About Your System 51