Dell PowerEdge R415 Hardware Owner's Manual - Page 28
CPU Bus parity, Check PSU.
View all Dell PowerEdge R415 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code E1420 E1421 E1422 E1610 E1614 E1618 Text Causes Corrective Actions CPU Bus parity The system BIOS has error. Power reported a processor bus cycle AC. parity error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 181. CPU # initialization error. Power cycle AC. The system BIOS reported Remove AC power to the a processor initialization system for 10 seconds and error. restart the system. If the problem persists, see "Getting Help" on page 181. CPU # machine check error. Power cycle AC. The system BIOS has reported a machine check error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 181. Power Supply # Specified power supply See "Troubleshooting (### W) was removed or is missing Power Supplies" on missing. from the system. page 155. Check power supply. Power Supply # Specified power supply (### W) error. has failed. Check power supply. See "Troubleshooting Power Supplies" on page 155. Predictive An over-temperature See "Troubleshooting failure on condition or power supply Power Supplies" on Power Supply # communication error has page 155. (### W). caused the predictive Check PSU. warning of an impending power supply failure. 28 About Your System