Table 1-2. LCD Status Messages (Optional) (continued) Code E1716 E1717 E171F Text Causes Corrective Actions Chipset IERR The system BIOS reported Check the SEL for more Bus ## Dev ## a chipset internal error information, and then Function ##. that resides in bus ##, clear the SEL. Remove Review & clear device ##, function ##. AC power to the system SEL. for 10 seconds, and restart the system. If the problem persists, see "Getting Help" on page 181. CPU # internal The system BIOS error. Review determined that the & clear SEL. specified processor has had an internal error. Check the SEL for more information, and then clear the SEL. Remove AC power to the system for 10 seconds, and restart the system. If the problem persists, see "Getting Help" on page 181. PCIe fatal error on Bus ## Device ## Function ## The system BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##. Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 165. PCIe fatal error on Slot #. Review & clear SEL. The system BIOS reported Remove and reseat the a PCIe fatal error on a expansion-card riser. See component that resides in "Expansion Card and the specified slot. Expansion-Card Riser" on page 99. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 181. 32 About Your System