Dell PowerEdge R415 Hardware Owner's Manual - Page 27
Check CPU or, E1410 System Fatal - technical guide
View all Dell PowerEdge R415 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code E1410 E1414 E1418 E141C E141F Text Causes Corrective Actions System Fatal Error detected. A fatal system error detected. Check LCD for additional scrolling messages. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 181. CPU # temp exceeding range. Check CPU heatsink. Specified processor is out Ensure that the processor of acceptable temperature heat sinks are properly range. installed. See "Troubleshooting the Processors" on page 166 and "Troubleshooting System Cooling Problems" on page 156. CPU # not detected. Check CPU is seated properly. Specified processor is missing or bad, and the system is in an unsupported configuration. Ensure that the specified microprocessor is properly installed. See "Troubleshooting the Processors" on page 166. Unsupported Processors are in an CPU unsupported configuration. configuration. Check CPU or BIOS revision. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system's Getting Started Guide. CPU # protocol The system BIOS error. Power has reported a processor cycle AC. protocol error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 181. About Your System 27