Denon AVR-5805MK2 Owners Manual - Page 43

Check the Parameter

Page 43 highlights

Microphone Amplifier Gain Setting using Sound Level Meter and RMS Volt Meter First you will need to adjust the " microphone amplifier gain". (1) Connect the all speakers and the video monitor (for the on-screen display) with the AVR-5805 (2) Connect the microphone with the microphone amplifier (3) Turn on the AVR-5805 and the "microphone amplifier" (4) Turn on the "Phantom Supply" on the microphone amplifier Pressure level with SPL meter at the microphone point. Adjust AVR volume SPL meter = 80 dB (C) AVR-5805 Speaker Microphone MIC AMP with mic power supply ex. mixer amp. 120 mVrms Use the internal test tones for mic amp calibration. Measure the output level and adjust the mic amp gain to 120 mVrms using a RMS volt meter. (5) Set the Parameter "Test Tone" to "Manual" and "Test Tone Start" to "Yes" at "2-4. Channel Level". (See pages 51, 52) (6) Once the test tone for Front Left (FL) speaker starts, check the Sound Pressure Level at the Listening Position with an SPL Meter. You do not have to check any of the other channels. (7) Adjust the "Main Volume" so that the Sound Pressure Level measures 80 dB (C-weighted) (8) Once the "Main Volume" as been set, connect the output of microphone amplifier to the RMS Volt Meter (9) Adjust the "microphone amplifier's gain" as the RMS Volt Meter becomes about 120 [mV RMS] (10) Once set, exit out of "System Setup" and turn off the AVR-5805 (11) Connect the output of the microphone amplifier to the AVR-5805's front panel "V.AUX" Left channel audio input-located behind Trap Door (12) Change the setting to "V.AUX L" at "1-4. Mic Input Select". (See pages 42, 43) (13) Start "Auto Setup". (See pages 33~39) 1-5. Check the Parameter • The results of the measured items can be checked. • The EQ parameters that were set in Auto Setup can be checked. • This item is automatically displayed, after the measurement result of the "Auto Setup / Room EQ" is decided. 1 Select "Parameter Check" at the Auto Setup / Room EQ Menu. CH SEL ENTER *AutoSet/RoomEQ Parameter Check (Main unit) (Remote control unit) 2 Display the Parameter Check screen. CH SEL ENTER (Main unit) (Remote control unit) *ParameterCheck Sp Config.Check Yes 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

43
Micr
ophone Amplifier Gain Setting using Sound Level Meter and RMS V
olt Meter
First you will need to adjust the “ microphone amplifier gain”.
(1)
Connect the all speakers and the video monitor (for the on-screen display) with the AVR-5805
(2)
Connect the microphone with the microphone amplifier
(3)
Turn on the AVR-5805 and the “microphone amplifier”
(4)
Turn on the “Phantom Supply” on the microphone amplifier
(5)
Set the Parameter “Test Tone” to “Manual” and “Test Tone Start” to “Yes” at “2-4. Channel Level”. (See pages 51, 52)
(6)
Once the test tone for Front Left (FL) speaker starts, check the Sound Pressure Level at the Listening Position with an SPL Meter. You
do not have to check any of the other channels.
(7)
Adjust the “Main Volume” so that the Sound Pressure Level measures 80 dB (C-weighted)
(8)
Once the “Main Volume” as been set, connect the output of microphone amplifier to the RMS Volt Meter
(9)
Adjust the “microphone amplifier’s gain” as the RMS Volt Meter becomes about 120 [mV RMS]
(10)
Once set, exit out of “System Setup” and turn off the AVR-5805
(11)
Connect the output of the microphone amplifier to the AVR-5805’s front panel “V.AUX” Left channel audio input–located behind Trap Door
(12)
Change the setting to “V.AUX L” at “1-4. Mic Input Select”. (See pages 42, 43)
(13)
Start “Auto Setup”. (See pages 33~39)
AVR-5805
Speaker
Microphone
Use the internal test tones for
mic amp calibration.
Pressure level with SPL meter at the
microphone point.
Adjust AVR volume SPL meter = 80 dB (C)
MIC AMP with mic
power supply ex.
mixer amp.
Measure the output level and
adjust the mic amp gain to 120
mVrms using a RMS volt meter.
120 mVrms
1-5. Check the Parameter
1
Select “Parameter Check” at the Auto Setup / Room
EQ Menu.
CH SEL
ENTER
(Main unit)
(Remote control unit)
The results of the measured items can be checked.
The EQ parameters that were set in Auto Setup can be checked.
This item is automatically displayed, after the measurement result of the “Auto Setup / Room EQ” is decided.
2
Display the Parameter Check screen.
CH SEL
ENTER
(Main unit)
(Remote control unit)
1−5.Parameter
Check
Delay
Time
Check
Speaker
Config.Check
Channel
Level
Check
Crossover
Freq.Check
EQ
Parameter
Check
Restore
Exit
Yes
1.Auto
Setup
2.Room
EQ
Setup
3.Direct
Mode
Setup
4.Mic
Input
Select
5.Parameter
Check
Exit
1.Auto
Setup/Room
EQ
Parameter Check
*AutoSet/RoomEQ
Sp Config.Check
*ParameterCheck