Fluke 744 Fluke 744 Users Manual - Page 117
DC Current Measurement, Resistance Measurement, Range, Resolution, of Reading +% of Full Scale
View all Fluke 744 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
Documenting Process Calibrator Specifications DC Current Measurement Range Resolution 30 mA 110 mA 1 µA 10 µA % of Reading +% of Full Scale 1 Year 2 Year 0.01% + 0.015% 0.02% + 0.015% 0.01% + 0.015% 0.02% + 0.015% Temperature Coefficient: (0.001% of rdg. + 0.002% f.s.)/°C in the ranges -10 to 18°C and 28 to 50°C Common Mode Error: 0.01% f.s./(Common Mode Volt) Maximum Input Voltage: 30 V dc Resistance Measurement Range Resolution 11 Ω 110 Ω 0.001 Ω 0.01 Ω 1 Year % of Reading + ohms 2 Year 0.05% + 0.05 0.075% + 0.05 0.05% + 0.05 0.075% + 0.05 1.1 k Ω 0.1 Ω 0.05% + 0.5 11 k Ω 1 Ω 0.1% + 10 Temperature Coefficient: (0.01% f.s. + 2 m Ω) /°C in the ranges -10 to 18°C and 28 to 50°C Common Mode Error: 0.005% f.s/(Common Mode Volt) Maximum Input Voltage: 30 V dc 0.075% + 0.5 0.1% + 10 107