HP StorageWorks 2/32 Brocade Fabric OS Message Reference - Supporting Fabric O
HP StorageWorks 2/32 - SAN Switch Manual
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/32 manual content summary:
- HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 1
53-1000437-01 15 June 2007 Fabric OS Message Reference Supporting Fabric OS v5.3.0 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 2
, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 3
The following table lists all versions of the Brocade Fabric OS Message Reference. Document Title Publication Number -08 Update software and hardware support March 2004 Fabric OS System Error Message 53-0000515-09 Updated for v4.4.0, Reference Manual First RASLog release August 2004 Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 4
iv Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 5
Auditing 2 System Logging Daemon (syslogd 3 System Console 3 Port Logs 4 Viewing and Configuring System Message Logs 4 Viewing System 11 Gathering Information About the Problem 12 Support 12 Panic Dump and Core Dump Files 12 Trace Dumps 13 supportSave Command 13 Fabric OS Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 6
-1015 29 AG-1016 29 AG-1017 29 AG-1018 29 AUTH System Messages AUTH-1001 31 AUTH-1002 31 AUTH-1003 31 AUTH-1004 32 AUTH-1005 32 AUTH-1006 32 AUTH-1007 32 AUTH-1008 33 AUTH-1010 33 AUTH-1011 33 vi Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 7
Chapter 4 Chapter 5 AUTH-1012 34 AUTH-1013 34 AUTH-1014 34 AUTH-1016 34 AUTH-1017 35 AUTH-1018 35 AUTH-1020 35 AUTH-1022 36 AUTH-1023 36 AUTH-1025 37 AUTH-1026 37 AUTH-1027 37 AUTH-1028 38 AUTH-1029 38 AUTH-1030 38 AUTH-1031 39 AUTH-1032 39 AUTH-1033 39 AUTH-1034 40 AUTH-1035 40 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 8
Chapter 6 BL-1003 48 BL-1004 48 BL-1006 48 BL-1007 49 BL-1008 49 BL-1009 49 BL-1010 50 BL-1011 50 BL-1012 51 BL-1013 51 BL-1014 51 BL- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 9
BM-1004 62 BM-1005 62 BM-1006 62 BM-1007 63 BM-1008 63 BM-1009 63 BM-1054 63 BM-1055 64 BM-1056 64 BM-1058 64 Chapter 8 CDR System Messages CDR-1001 65 CDR-1002 65 CDR-1003 65 CDR-1004 66 Chapter 9 CER System Messages CER-1001 67 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 10
EM-1006 73 EM-1007 73 EM-1008 73 EM-1009 74 EM-1010 74 EM-1011 74 EM-1012 75 EM-1013 75 EM-1014 75 EM-1015 76 EM-1016 76 EM-1017 76 EM-1018 77 EM-1019 77 EM-1028 77 EM-1029 78 EM-1031 78 EM-1033 78 EM-1034 79 EM-1035 79 EM-1036 80 EM-1037 80 EM-1041 80 EM-1042 81 EM-1043 81 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 11
EM-1060 85 EM-1061 85 EM-1062 86 EM-1063 86 EM-1064 86 EM-1065 87 EM-1066 87 EM-2003 87 Chapter 12 EVMD System Messages EVMD-1001 89 Chapter 13 FABR System Messages FABR-1001 91 FABR-1002 91 FABR-1003 91 FABR-1004 92 FABR-1005 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 12
104 FABS-1011 104 FABS-1012 104 FABS-1013 105 FABS-1014 105 FABS-1015 105 Chapter 15 FBC System Messages FBC-1001 107 Chapter 16 FCIP System Messages FCIP-1000 109 Chapter 17 FCMC System Messages FCMC-1001 111 Chapter 18 FCPD System Messages FCPD-1001 113 FCPD-1002 113 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 13
Chapter 20 FCR System Messages FCR-1001 117 FCR-1002 117 FCR-1003 117 FCR-1004 118 FCR-1005 118 FCR-1006 118 FCR-1007 118 FCR-1008 119 FCR-1009 119 FCR-1010 119 FCR-1011 119 FCR-1012 120 FCR-1013 120 FCR-1015 120 FCR-1016 120 FCR-1018 121 FCR-1019 121 FCR-1020 121 FCR-1021 122 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 14
FCR-1039 127 FCR-1040 127 FCR-1041 127 FCR-1042 128 FCR-1043 128 FCR-1048 128 FCR-1049 129 FCR-1053 129 FCR-1054 129 FCR-1055 130 FCR-1056 130 FCR-1057 130 FCR-1058 130 FCR-1059 131 FCR-1060 131 FCR-1061 131 FCR-1062 132 FCR-1063 132 FCR-1064 132 FCR-1065 132 FCR-1066 133 FCR- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 15
FICU-1005 140 FICU-1006 140 FICU-1007 141 FICU-1008 141 FICU-1009 141 FICU-1010 142 Chapter 22 FKLB System Messages FKLB-1001 143 Chapter 23 FLOD System Messages FLOD-1001 145 FLOD-1003 145 FLOD-1004 145 FLOD-1005 146 FLOD-1006 146 Chapter 24 FSPF System Messages FSPF-1001 147 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 16
Chapter 27 FW System Messages FW-1001 155 FW-1002 155 FW-1003 156 FW-1004 156 FW-1005 156 FW-1006 157 FW-1007 157 FW-1008 157 FW-1009 158 FW-1010 158 FW-1011 158 FW-1012 159 FW-1033 159 FW-1034 159 FW-1035 160 FW-1036 160 FW-1037 160 FW-1038 161 FW-1039 161 FW-1040 161 FW-1041 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 17
Fabric OS Message Reference 53-1000437-01 FW-1117 167 FW-1118 168 FW-1119 168 FW-1120 169 FW-1121 169 FW-1122 169 FW-1123 170 FW-1124 170 FW-1125 170 FW-1126 171 FW-1127 171 FW-1128 172 FW-1129 172 FW-1130 172 FW-1131 173 FW-1132 173 FW-1133 173 FW-1134 174 FW-1135 174 FW-1136 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 18
FW-1173 180 FW-1174 181 FW-1175 181 FW-1176 181 FW-1177 182 FW-1178 182 FW-1179 182 FW-1180 183 FW-1181 183 FW-1182 183 FW-1183 184 FW-1184 184 FW-1185 184 FW-1186 185 FW-1187 185 FW-1188 185 FW-1189 186 FW-1190 186 FW-1191 186 FW-1192 187 FW-1193 187 FW-1194 187 FW-1195 188 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 19
FW-1303 197 FW-1304 198 FW-1305 198 FW-1306 198 FW-1307 199 FW-1308 199 FW-1309 199 FW-1310 200 FW-1311 200 FW-1312 200 FW-1313 201 FW-1314 201 FW-1315 201 FW-1316 202 FW-1317 202 FW-1318 202 FW-1319 203 FW-1320 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 20
FW-1327 205 FW-1328 206 FW-1329 206 FW-1330 206 FW-1331 207 FW-1332 207 FW-1333 207 FW-1334 208 FW-1335 208 FW-1336 208 FW-1337 209 FW-1338 209 FW-1339 210 FW-1340 210 FW-1341 210 FW-1342 211 FW-1343 211 FW-1344 211 FW-1345 212 FW-1346 212 FW-1347 213 FW-1348 213 FW-1349 214 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 21
Fabric OS Message Reference 53-1000437-01 FW-1364 220 FW-1365 220 FW-1366 220 FW-1367 221 FW-1368 221 FW-1369 221 FW-1370 222 FW-1371 222 FW-1372 222 FW-1373 223 FW-1374 223 FW-1375 223 FW-1376 224 FW-1377 224 FW-1378 224 FW-1379 225 FW-1400 225 FW-1401 225 FW-1402 226 FW-1403 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 22
FW-1441 232 FW-1442 232 FW-1443 232 FW-1444 233 FW-1445 233 FW-1446 233 FW-1500 234 FW-1501 234 Chapter 28 HAM System Messages HAM-1001 235 HAM-1002 235 HAM-1004 235 HAM-1005 236 HAM-1006 236 Chapter 29 HAMK System Messages HAMK-1001 239 HAMK-1002 239 HAMK-1003 239 HAMK-1004 240 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 23
252 HIL-1510 252 HIL-1601 253 HIL-1602 253 Chapter 31 HLO System Messages HLO-1001 255 HLO-1002 255 HLO-1003 255 Chapter 32 HMON System Messages HMON-1001 257 Chapter 33 HTTP System Messages HTTP-1001 259 Fabric OS Message Reference xxiii 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 24
HTTP-1002 259 HTTP-1003 259 Chapter 34 IBD System Messages IBD-1001 261 Chapter 35 IBPD System Messages IBPD-1001 263 IBPD-1002 263 IBPD-1003 263 Chapter 36 ICPD System Messages ICPD-1001 265 ICPD-1002 265 ICPD-1003 265 ICPD-1004 266 ICPD-1005 266 ICPD-1006 266 ICPD-1007 266 ICPD- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 25
ISNS-1003 275 ISNS-1004 276 ISNS-1005 276 ISNS-1006 276 ISNS-1008 277 ISNS-1009 277 ISNS-1010 277 ISNS-1011 277 ISNS-1013 278 ISNS-1014 278 Chapter 41 KSWD System Messages KSWD-1003 279 Chapter 42 KTRC System Messages KTRC-1001 281 KTRC-1002 281 KTRC-1003 281 KTRC-1004 281 KTRC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 26
Chapter 46 MPTH System Messages MPTH-1001 289 MPTH-1002 289 MPTH-1003 289 Chapter 47 MQ System Messages MQ-1004 291 Chapter 48 MS System Messages MS-1001 293 MS-1002 293 MS-1003 294 MS-1004 294 MS-1005 295 MS-1006 295 MS-1008 295 MS- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 27
PDTR System Messages PDTR-1001 311 PDTR-1002 311 Chapter 53 PLAT System Messages PLAT-1000 313 PLAT-1001 313 Chapter 54 PORT System Messages PORT-1003 315 PORT-1004 315 PORT-1005 316 Chapter 55 PS System Messages PS-1000 317 PS-1001 317 PS-1002 317 PS-1003 318 PS-1004 318 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 28
Chapter 56 PSWP System Messages PSWP-1001 319 PSWP-1002 319 PSWP-1003 319 Chapter 57 RAS System Messages RAS-1001 321 RAS-1002 321 RAS-1003 321 RAS-1004 322 RAS-1005 322 Chapter 58 RCS System Messages RCS-1001 323 RCS-1002 323 RCS-1003 323 RCS-1004 324 RCS-1005 324 RCS-1006 325 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 29
Chapter 62 SCN System Messages SCN-1001 333 Chapter 63 SEC System Messages SEC-1001 335 SEC-1002 335 SEC-1003 336 SEC-1005 336 SEC-1006 336 SEC-1007 337 SEC-1008 337 SEC-1009 337 SEC-1016 338 SEC-1022 338 SEC-1024 338 SEC-1025 339 SEC-1026 339 SEC-1028 339 SEC-1029 340 SEC-1030 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 30
SEC-1051 346 SEC-1052 346 SEC-1053 346 SEC-1054 347 SEC-1055 347 SEC-1056 347 SEC-1057 348 SEC-1059 348 SEC-1062 348 SEC-1063 349 SEC-1064 349 SEC-1065 349 SEC-1069 349 SEC-1071 350 SEC-1072 350 SEC-1073 350 SEC-1074 351 SEC-1075 351 SEC-1076 351 SEC-1077 352 SEC-1078 352 SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 31
Fabric OS Message Reference 53-1000437-01 SEC-1095 358 SEC-1096 358 SEC-1097 358 SEC-1098 359 SEC-1099 359 SEC-1100 359 SEC-1101 360 SEC-1102 360 SEC-1104 360 SEC-1105 361 SEC-1106 361 SEC-1107 361 SEC-1108 362 SEC-1110 362 SEC-1111 362 SEC-1112 363 SEC-1115 363 SEC-1116 363 SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 32
SEC-1155 370 SEC-1156 370 SEC-1157 370 SEC-1158 371 SEC-1159 371 SEC-1160 371 SEC-1163 372 SEC-1164 372 SEC-1165 372 SEC-1166 373 SEC-1167 373 SEC-1168 373 SEC-1170 374 SEC-1171 374 SEC-1172 374 SEC-1173 375 SEC-1174 375 SEC-1175 375 SEC-1176 375 SEC-1180 376 SEC-1181 376 SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 33
Fabric OS Message Reference 53-1000437-01 SEC-1198 381 SEC-1199 382 SEC-1200 382 SEC-1201 382 SEC-1202 383 SEC-1203 383 SEC-1250 383 SEC-1251 384 SEC-1253 384 SEC-1300 384 SEC-1301 385 SEC-1302 385 SEC-1303 385 SEC-1304 386 SEC-1305 386 SEC-1306 386 SEC-1307 387 SEC-1308 387 SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 34
SEC-1328 393 SEC-1329 393 SEC-1330 393 SEC-1331 394 Chapter 64 SNMP System Messages SNMP-1001 395 SNMP-1002 395 SNMP-1003 395 SNMP-1004 396 SNMP-1005 396 SNMP-1006 396 Chapter 65 SS System - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 35
SULB-1031 410 SULB-1033 410 SULB-1034 411 SULB-1035 411 SULB-1036 411 SULB-1037 411 Chapter 67 SWCH System Messages SWCH-1001 413 SWCH-1002 413 SWCH-1003 413 SWCH-1004 414 SWCH-1005 414 SWCH-1006 414 SWCH-1007 415 SWCH-1008 415 Chapter 68 SYSC System Messages SYSC-1001 417 SYSC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 36
TRCE-1005 422 TRCE-1006 423 TRCE-1007 423 TRCE-1008 423 TRCE-1009 424 TRCE-1010 424 TRCE-1011 424 TRCE-1012 425 Chapter 71 TRCK System Messages TRCK-1001 427 TRCK-1002 427 TRCK-1003 427 TRCK-1004 428 TRCK-1005 428 TRCK-1006 428 Chapter 72 TS System Messages TS-1001 429 TS-1002 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 37
WEBD-1006 438 WEBD-1007 438 WEBD-1008 439 Chapter 76 ZOLB System Messages ZOLB-1001 441 Chapter 77 ZONE System Messages ZONE-1002 443 ZONE-1003 443 ZONE-1004 444 ZONE-1005 444 ZONE-1006 445 ZONE-1007 445 ZONE-1008 445 ZONE-1010 446 ZONE-1012 446 ZONE-1013 446 ZONE-1014 447 ZONE- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 38
xxxviii ZONE-1037 454 ZONE-1038 454 ZONE-1039 454 ZONE-1040 455 ZONE-1041 455 ZONE-1042 455 ZONE-1043 455 ZONE-1044 456 ZONE-1045 456 ZONE-1046 456 Chapter 78 AUDIT AUTH System Messages AUTH-3001 457 AUTH-3002 457 AUTH-3003 457 AUTH-3004 458 AUTH-3005 458 AUTH-3006 458 AUTH-3007 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 39
SEC-3008 467 SEC-3009 468 SEC-3010 468 SEC-3011 468 SEC-3012 469 SEC-3013 469 SEC-3014 469 SEC-3015 470 SEC-3016 470 SEC-3017 470 SEC-3018 471 SEC-3019 471 SEC-3020 471 SEC-3021 472 SEC-3022 472 SEC-3023 472 SEC-3024 473 SEC-3025 473 SEC-3026 473 SEC-3027 474 SEC-3028 474 SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 40
Chapter 83 AUDIT SULB System Messages SULB-1001 481 SULB-1002 481 SULB-1003 481 SULB-1009 482 SULB-1010 488 SULB-1017 488 SULB-1018 488 SULB-1020 488 SULB-1021 489 SULB-1023 489 SULB-1024 489 SULB-1026 490 SULB-1030 490 SULB-1031 490 SULB-1033 491 SULB-1034 491 SULB-1035 491 SULB- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 41
ZONE-3017 498 ZONE-3018 499 ZONE-3019 499 ZONE-3020 499 ZONE-3021 500 ZONE-3022 500 ZONE-3023 500 ZONE-3024 501 ZONE-3025 501 Fabric OS Message Reference xli 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 42
xlii Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 43
Fabric OS v5.2.0 to 5.3.0, supporting the following platforms: • Brocade 200E, 4012, 4016, 4018, 4020, 4024 switches • Brocade 3250 switch • Brocade 3850 switch • Brocade 3900 switch • Brocade 4100, 4900, 5000, 7500, AP 7600 switches • Brocade 24000 director Fabric OS Message Reference xlvii 53 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 44
• Brocade 48000 director • FA4-16 blade • FC10-6 blade In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 45
names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a command is case sensitive. NOTES, CAUTIONS, AND WARNINGS The - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 46
of Brocade switches over dark fiber or dense wave division multiplexing (DWDM) equipment at distances up to 500 kilometers to enhance business continuance operations. Fabric Watch Continuously monitors SAN fabrics for potential faults based on thresholds set for a variety of SAN fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 47
ideal for optimizing performance and simplifying the management of multi-switch SAN fabrics containing Brocade 1, 2, and 4 Gbit/sec switches and directors. When two or more adjacent ISLs are used to connect two switches, the switches automatically group the ISLs into a single logical ISL, or "trunk - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 48
wall to the left of the ports. 3. World Wide Name (WWN) - Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, AP7600 switches and Brocade 24000, and 48000 directors: Provide the license ID. Use the licenseIdShow command to display the license ID. Document Feedback - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 49
guide supports Fabric OS v5.3.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability • Port Logs 4 SYSTEM ERROR MESSAGE LOGGING The RASLog service generates - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 50
command. The sequence number is persistent across power cycles and switch reboots. • By default, the errDump and errShow commands support post-event audtis and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 51
on configuring syslogd functionality, refer to the Fabric OS Administrator's Guide. SYSTEM CONSOLE The system console displays messages only through the serial port. If you log in to a switch through the Ethernet port or modem port, you will not receive system console messages. Fabric OS Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 52
oldest log entries. Port logs capture switch-to-device, device-to-switch, switch-to-switch, some device A-to-device B, and control information. Port logs are not persistent and are lost over power cycles and reboots. Run the portLogShow command to display the port logs for a particular port. Run the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 53
portLogTypeEnable Enables an event to report to the port log. Port log events are described by the portLogEventShow command. setVerbose Sets the verbose level of a particular module within the Fabric OS. supportFtp Sets, clears, or displays support FTP parameters or a time interval to check the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 54
can take several minutes. supportShow Executes a list of diagnostic and error display commands. This output is used by your switch service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogDIpAdd Adds an IP address as a recipient of - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 55
3,, WARNING, switch, Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue, Q to stop: CLEARING THE SYSTEM MESSAGE LOG To clear the system message log for a particular switch instance: 1. Log in to the switch as admin. 2. Use the errClear command to clear all - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 56
FIRMWARE /07/22-10:12:33, [EM switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. Displays the message module and number. These values uniquely identify each message in the Fabric OS and reference the cause and actions recommended in this manual - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 57
command. The sequence number is persistent across power cycles and switch switch name or the chassis name of the switch. This value is truncated if it exceeds 16 characters in length. Run either the chassisName command to name the chassis or the switchName command to rename the logical switch problem - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 58
Description AUDIT 2005/12/10-09:54:03 Audit flag Date and Time Stamp Identifies the message as an Audit message. The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. [SEC-1000 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 59
in redundant mode unless the failed power supply is replaced or fixed. Problem 12 • Support 12 • Panic Dump and Core Dump Files 12 • Trace Dumps 13 • supportSave Command 13 LOOKING UP A SYSTEM MESSAGE Error messages in this manual for each message: • Module and code name for the error • Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 60
serial port (console) logs available? 12. Which CP was master? (only applicable to the Brocade 12000, 24000, or 48000) 13. What and when were the last actions or changes made to the system? SUPPORT Fabric OS create a number of files that can help support personnel troubleshoot and diagnose a problem - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 61
support when requested. SUPPORTSAVE COMMAND The supportSave command can be used to send the output of the system messages (RASLog), the trace files, and the output of the supportShow command to an off-switch storage location via FTP. Prior to running the supportSave command, you can optionally set - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 62
module on the Brocade director platforms. Status messages for configUpload and configDownload operations. The environmental monitor (EM) manages and monitors the various field replaceable units (FRUs), including the port cards, control processor (CP) blades, blower assemblies, power supplies, and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 63
, to establish the identity of the neighbor switch, and to exchange FSPF parameters and capabilities. Health monitor. HTTP error messages. This raslog generates messages related to port restart failure. IBPD stands for iSCSI gateway daemon on a blade processor (BP). It manages iSCSI initiator access - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 64
Blade Manager (bmd) • Common Access Layer (cald) • Diagnostics daemon (diagd) • Environment Monitor (emd) • EVM daemon (evmd) • Exchange Service Support secd) • SNMP daemon (snmpd) • Time Service daemon (tsd) • TRACE daemon (traced) status of port links. This unit port (FICON interrupt service routine - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 65
an "unreachable" message to the caller, allowing the caller to take the appropriate action. If a switch is not responding, RTWR retries 100 times. Storage application services supporting director-class storage virtualization platform. The internal state change notification daemon is used for state - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 66
software upgrade library provides firmwareDownload command capability, which enables firmware upgrades to both CP blades with a single command, as well as nondisruptive code load to all 4.x switches. These messages might display if there are any problems during the firmwareDownload procedure. Most - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 67
RASLog Messages This section provides the RASLog messages, including: • AG System Messages 25 • AUTH System Messages 31 • BKSW System Messages 45 • BL System Messages 47 • BLL System Messages 59 • BM System Messages 61 • CDR System Messages 65 • CER System Messages 67 • CONF System Messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 68
293 • NBFS System Messages 299 • NS System Messages 301 • PDM System Messages 303 • PDTR System Messages 311 • PLAT System Messages 313 • PORT System Messages 315 • PS System Messages 317 • PSWP System Messages 319 • RAS System Messages 321 • RCS System Messages 323 • RPCD System Messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 69
• UPTH System Messages 435 • WEBD System Messages 437 • ZOLB System Messages 441 • ZONE System Messages 443 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 70
- HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 71
Audit Log Messages This section provides the Audit messages, including: • AUDIT AUTH System Messages 457 • AUDIT CONF System Messages 461 • AUDIT HTTP System Messages 463 • AUDIT SEC System Messages 465 • AUDIT SNMP System Messages 479 • AUDIT SULB System Messages 481 • AUDIT ZONE System - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 72
- HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 73
Action • On Brocade, Fabric OS based switches execute the portCfgNpivPort command on the fabric switch to enable NPIV capability on the port connected to the Access Gateway. Refer to the Fabric OS Command Reference manual for more information on this command. • Some blades within a switch or some - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 74
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AG-1005 Message , [AG-1005], ,, WARNING, , FDISC response was dropped because F_Port is offline. Probable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 75
-name>, Invalid port login (PLOGI) response from the fabric on the N_Port . Probable Cause Indicates that the fabric switch management server did (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 76
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. command and contact your switch service provider. Severity WARNING AG-1013 Message , [AG-1013], ,, INFO, , F_Ports mapped to N_Port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 77
run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1016 display the status of all ports in the system. Run portCfgShow to display a list of Action ports currently configured as N_Port(s). - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 78
2 AG-1018 Recommended Run switchShow to display the status of all ports in the system. Run portCfgShow to display a list of Action ports currently configured as N_Port(s). Ensure that the host is connected to an F_port. Severity ERROR 30 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 79
. The values for Operation type can be "set" or "remove". Recommended Action Retry the secAuthSecret command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 80
exist: . Probable Cause Indicates an authentication file corruption. Recommended Action Run the firmwareDownload command to reinstall the firmware. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 81
code>. Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 82
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 83
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 84
needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1023 Message , [AUTH-1023], ,, ERROR, , Failed to during : port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 85
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1026 Message , [AUTH-1026], ,, WARNING, , Failed to get during negotiation phase: port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 86
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1030 Message , [AUTH-1030], ,, ERROR, , Invalid message code for message: port . 38 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 87
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1033 Message , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 88
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1036 Message , [AUTH-1036], ,, ERROR, , Invalid state for : port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 89
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1039 Message Probable Cause , [AUTH-1039], ,, ERROR, , Neighboring switch has conflicting authentication policy: Port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 90
supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1042 Message Probable Cause , [AUTH-1042], ,, ERROR, , Port has been disabled, because - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 91
to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1043 Message , [AUTH-1043], ,, ERROR, , Failed to enforce device authentication mode:(error: - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 92
3 AUTH-1044 44 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 93
daemons is found to be nonresponsive; sending signal abort. Recommended Action Run the supportSave command to determine if any core files were created. If a core file is found, information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 45 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 94
4 BKSW-1003 46 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 95
correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Note that any reference seen to slot 0 is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 96
not faulted due to a user setting. Recommended Action Reboot or power cycle the blade, using the slotPowerOff and slotPowerOn commands. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 97
. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 98
port. Run the systemVerification command to verify that the blade or switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 99
factor pluggable (SFP), or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade. Severity ERROR BL-1014 Message Probable Cause , [BL - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 100
error. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade, 24000, and 48000, replace the blade field-replaceable unit (FRU - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 101
blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power slot has completed initializing the ports. Recommended No action is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 102
one or more of the internal ports was not online. The switch is faulted. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 103
Action Reboot or power cycle the blade. If the message persists, replace the blade. Severity CRITICAL BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 104
supportSave information, then reboot switch and run the diagPost command to ensure Action Power-On Self-Test (POST) is enabled. If problem persists, replace switch. Severity CRITICAL BL-1027 Message , [BL-1027], ,, CRITICAL, , Blade in slot - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 105
Indicates that back-end (non-user) ports have not come ONLINE within time limit. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 106
waiting for disable messages from the user ports after disabling the ports. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 107
Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 108
6 BLL-1000 If the message persists, replace the blade. Severity CRITICAL 60 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 109
either the control processor (CP) or on the application processor (AP) blade. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmware download is supported between the versions. As the AP and CP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 110
and slotPoweron commands or reseat the affected blade. On the Brocade Action 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity WARNING BM-1004 Message , [BM-1004], ,, INFO, , Blade firmware on - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 111
commands or reseat the affected blade. On the Brocade Action 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity WARNING BM-1054 Message Probable Cause , [BM-1054], ,, INFO, , AP firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 112
. Probable Cause The firmwareDownload command on the application processor (AP) blade failed. Recommended Use the slotPoweroff and slotPoweron commands or reseat the affected blade. On the Brocade Action 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 113
, , Port chip faulted due to internal error. Probable Cause Internal error. Recommended For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover Action the system. For a non-bladed system, perform fastBoot on the switch to recover the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 114
specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Whenever this error occurs, reboot the system at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR 66 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 115
loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended Action Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS on the active - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 116
9 CER-1001 68 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 117
Chapter CONF System Messages 10 CONF-1000 Message , [CONF-1000], , AUDIT, INFO, , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 118
switch and try to download configuration again. Action Severity INFO CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable Cause Previous configuration commands - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 119
of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow command to is faulted. Recommended Action On Brocade 24000 and 48000, try reseating the specified FRU. Reboot or power cycle the switch. Fabric OS Message Reference 71 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 120
the switch. Use the fanShow command to verify fans are operating properly. Make sure there are no blockages of the airflow around the chassis. If the temperature problem is isolated to the blade itself, replace the blade. Voltage problems on a blade are likely a hardware problem on the blade itself - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 121
likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade 24000 and 48000, replace the blade field-replaceable unit (FRU). For the Brocade 3900 replace the motherboard FRU. For the Brocade 200E, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 122
FRU. Refer to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 to be powered up after four seconds. Recommended Try reseating the blade. If this fails to correct the error, replace the blade. Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 123
problems on the switch. Recommended Action On Brocade 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch FRU Id> () Probable Cause Indicates - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 124
that a problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 125
specified FRU. The return code is for internal use only. This is a serious hardware problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. Recommended Action If the message persists, reboot or power cycle the switch. If the message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 126
the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in set to faulty - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 127
Id> set to faulty, rc=. Probable Cause Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified reason. Recommended Action Try reseating the FRU. Run the systemVerification command to verify that the switch does not have hardware problems - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 128
the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. If the message persists, replace the FRU. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 129
down Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on because the associated logical switch is shut down. Recommended Run the switchStart command on the associated logical switch. Action Severity WARNING Fabric OS Message Reference 81 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 130
is indicating a predicted failure. If new_state is Down (not enough power), a newly inserted port blade was not powered on because there was not enough power available. Recommended The Brocade 24000 requires only a single power supply for a fully populated chassis; however, you Action should always - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 131
access to the field-replaceable unit (FRU) has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 132
>,, WARNING, , : Port faulted. Reason: . Probable Cause Indicates a faulty port media is detected. The reason code for this message is for internal use only. This message is valid for only the Brocade 4100, 4900, 5000, 7500, and AP7600. Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 133
with your switch type. Action Severity CRITICAL EM-1060 Message , [EM-1060], ,, WARNING, , Stopping synchronization of the system due to blade incompatibility with software version on standby CP. Probable Cause A blade in the system is not supported by - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 134
Fault reason>. Probable Cause The blade is power off since a hardware (HW) application specific integrated circuit (ASIC) ERROR was detected, and the user has selected to power off the problem blade when such a condition occurred. Recommended Contact support. Action Severity CRITICAL 86 Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 135
either the control processor firmware (CFOS) or the blade processor firmware (BFOS) is not compatible with the Storage Application Services (SAS) or other application firmware version(s). Recommended Upgrade the FOS firmware or the SAS firmware with the firmwareDownload command. Refer to the Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 136
11 EM-2003 88 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 137
EVMD System Messages 12 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause The event could not be sent to the remote proxy because the remote proxy switch cannot be reached - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 138
12 EVMD-1001 90 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 139
Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent an invalid sized payload. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log for - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 140
frame. If it is due to problems with the kernel, the system will recover by performing a failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1005 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 141
problem with the Fabric OS. Recommended Action In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 142
message is rare and usually indicates a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FABR-1011 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 143
, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL FABR-1014 Message , [FABR-1014], , FFDC, ERROR, , Port Disabled: Insistent Domain ID - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 144
Probable Cause Indicates that a failure occurred when trying to set the principal switch using the fabricPrincipal command. The message notifies the user that the switch failed to become the principal switch because either: • The switch joined an existing fabric and bypassed the F0 state. • The - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 145
FABR-1019], , FFDC, CRITICAL, , Critical fabric size () exceeds supported configuration (). Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 146
, Fabric size () exceeds supported configuration (). Fabric limit timer () started from < Indicates that the fabric size has exceeded the limit set by your value-line switches. Value-line switches have a limited fabric size: a specified limit to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 147
buffer credits are fixed, based on the port configuration information. In this port exceeded. Probable Cause Indicates that fabric exhausted the maximum number of retries sending internal link service (ILS) to the iswitchd demon on the specified E_port. Recommended Run the top command - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 148
ID and switchname running an unsupported FOS version v2.x has joined the fabric. Probable Cause Indicates that a switch with an unsupported Fabric OS version 2.x has joined the fabric. Recommended Remove the switch with the unsupported Fabric OS version 2.x from the fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 149
by the software. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 150
state to blade driver Recommended Action If the message is isolated, monitor the error messages on the switch. If the error is repetitive or if the fabric failed, fail over or reboot the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 151
object's status field. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1008 Message , [FABS-1008], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 152
an unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message , [FABS-1011], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 153
code> Probable Cause Indicates the specified FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 154
14 FABS-1015 106 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 155
Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 156
15 FBC-1001 108 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 157
Chapter FCIP System Messages 16 FCIP-1000 Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid=< - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 158
16 FCIP-1000 110 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 159
is low on memory and failed to allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 160
17 FCMC-1001 112 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 161
Private devices will not respond to the switch port login (PLOGI) during probing. Recommended Action The Brocade 4100, 4900, 5000, 7500, and AP 7600 do not support private loop devices. Refer to the switch vendor for a list of other port types that support private devices for inclusion into the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 162
18 FCPD-1003 114 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 163
function call is "kmalloc_wrapper failed". This function call is for kernel memory allocation. Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over, and the standby CP will become the active CP. Severity CRITICAL - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 164
19 FCPH-1001 116 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 165
action is required. Action Severity INFO FCR-1003 Message , [FCR-1003], ,, INFO, ,FC router physical devices newly exported at port . Probable Cause Indicates that one or more physical devices have been newly exported through the specified - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 166
FCR-1007], ,, INFO, , FC router LSAN zone deleted at port . Probable Cause Indicates that a logical storage area network (LSAN) zone attached to the specified port was deleted from the edge fabric. Recommended No action is required. Action 118 Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 167
[FCR-1008], ,, INFO, , FC router LSAN zone created at port . Probable Cause Indicates that a logical storage area network (LSAN) zone was created at the specified port in the edge fabric. Recommended No action is required. Action Severity INFO FCR-1009 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 168
build completed on port . Probable Cause the specified port. Recommended No completed on port . or VEX_Port added on port in domain < on the specified port in the specified domain fabric no longer reachable at port id fabric ID - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 169
created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, limit: . Indicates that the number of logical storage area network (LSAN) zones created within a MetaSAN exceeds the local LSAN zone - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 170
device slots by using the fcrProxyConfig command or limit proxy devices by Action removing logical storage area network (LSAN) zone entries. Severity >, Local phantom port WWN entries exhausted. Indicates that the number of port world-wide names (WWNs) in use exceeds the local port WWN resources. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 171
limits the number of translate domain ports required) by limiting the devices specified in logical storage area network (LSAN) zones. Severity WARNING pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 172
>,, INFO, , In slot port WWN roll over. Probable Cause Indicates that the port world-wide name (WWN) pool has rolled over in pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 173
. Action Severity INFO FCR-1033 Message Probable Cause , [FCR-1033], ,, INFO, , Edge fabric disabled security on port in fabric . Indicates that Secure mode was turned off in the edge fabric. Fabric OS Message Reference 125 53 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 174
, , LSAN zone device added in the backbone fabric. Probable Cause Indicates that a new device was added to a logical storage area network (LSAN) zone in the backbone fabric. Recommended No action is required. Action Severity INFO FCR-1036 Message , [FCR-1036], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 175
of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones created is within the range of the local database limitations - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 176
that a logical storage area network (LSAN) zone set. Recommended Action Setting port credits failed. Execute the portEnable command. If the problem persists try rebooting the switch. If the message persists, collect switch information using the supportShow command, and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 177
Indicates an incoming exchange link protocol (ELP) command was issued and it is not supported. Recommended Action Run the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 178
edge routing is not needed. Otherwise replace the switch with Action one that supports backbone to edge routing. Severity INFO FCR- port configuration on both sides of the link using the portCfgShow command. Investigate the other switch for more details. Run the errShow command on the other switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 179
commands to restart authentication. Severity INFO FCR-1060 Message , [FCR-1060], ,, WARNING, , EX_Port() has an incompatible configuration setting. Probable Cause Indicates that virtual channel (VC) Link Init is enabled on the local switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 180
Port disabled, system only supports EX/VEX_ports. Probable Cause Indicates that the maximum number of supported Cause Indicates that the fabric ID of the switch does not match the local switch. Recommended Run the switchShow command to display the fabric ID. Change the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 181
Action If the fabric split, then merge the fabrics and manually re-enable the port. If there is another fabric with the same ID, change the fabric ID for the port using the portCfgExport or portCfgVExport commands. Severity ERROR FCR-1067 Message , [FCR-1067], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 182
--enable fcr, or a configDownload with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action number>,, INFO, , Port is changed from FCR port to non FCR port. Indicates that the port is no longer an EX_Port or - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 183
Recommended No action is required. Action Severity INFO 20 FCR-1072 Fabric OS Message Reference 135 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 184
Probable Cause Indicates that a switch in the backbone/edge that supports different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Please - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 185
[FCR-1076], ,, ERROR, , Port disabled, system only supports front domains. Probable Cause Indicates that the maximum number of supported front domains was exceeded. To enable the specified port, disable any other operational front domain and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 186
20 FCR-1076 138 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 187
function name>: config - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 188
, , : Failed to set fabric manager server (FMS) mode: conflicting PID port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference for more information on this command - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 189
be a transient problem. Recommended Action If the message persists, check the memory usage on the switch, using the memShow command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 190
Server mode (fmsMode) was not enabled because the specified port has an address conflict with the CUP management port is in use. Recommended Use the portDisable command to disable the specified port to avoid the port address conflict. Action Severity WARNING 142 Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 191
Chapter FKLB System Messages 22 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 192
22 FKLB-1001 144 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 193
, FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link that the LSU size exceeds what the system can support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 194
23 FLOD-1005 FLOD-1005 Message , [FLOD-1005], ,, WARNING, , Invalid received domain ID: Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required; the LSR is discarded. Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 195
Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is required. Action Severity ERROR FSPF-1002 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 196
port. The section ID is used to identify a set of switches that share an identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID. It should be set to 0 for a nonhierarchical fabric. Brocade switches support - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 197
if it is a nonbladed system. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], ,, WARNING, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 198
if it is a nonbladed system. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], ,, WARNING, , FSS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 199
as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 200
25 FSS-1007 152 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 201
HA state does not become synchronized, run the haDump command to diagnose the problem. If the problem persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 153 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 202
. In a non-bladed system, this message is logged when the firmware upgrade/downgrade was invoked. The new firmware version is not compatible with current running version. This cause a disruptive firmware upgrade/downgrade. Recommended For a dual CP system, run the firmwareDownload command to load - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 203
means that the fans and airflow of a switch are functioning normally. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING Fabric OS Message Reference 155 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 204
> . Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a that the speed of the fan has changed. Fan problems typically contribute to temperature problems. Recommended Action No action is required. Respond to this - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 205
is . Probable Cause Indicates that the speed of the fan has fallen below the low boundary. Fan problems typically contribute to temperature problems. Recommended Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan Action field-replaceable unit - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 206
Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity . Probable Cause Indicates that the power supply is functioning properly. Recommended Set the high boundary above the normal operation - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 207
>, is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value within the acceptable range. Recommended No action is required. Respond - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 208
(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive performance area measures the amount of incoming laser to help you determine if the SFP is in good working - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 209
value>, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The receive performance area measures the amount of incoming laser to help you determine if the SFP is in - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 210
High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed. The transmit performance area measures the amount of outgoing laser to help you determine if the SFP is in good working - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 211
value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed from acceptable range to a value within the acceptable range. The transmit performance area measures the amount of outgoing laser to help you determine if the SFP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 212
27 FW-1047 FW-1047 Message , [FW-1047], ,, WARNING, , , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 213
27 FW-1050 FW-1050 Message , [FW-1050], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 214
SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 215
fabric reconfigurations has changed. The following actions can cause a fabric reconfiguration: • two switches with the same domain ID have connected to one another. • two fabrics have error and might not require troubleshooting. Severity INFO Fabric OS Message Reference 167 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 216
below the low boundary. The following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. • Two fabrics have a transient error and might not require troubleshooting. Severity INFO 168 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 217
changes has changed. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 218
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 219
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. A low number of segmentation errors - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 220
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 221
Low=). Current value is . Probable Cause Indicates that the number of fabric logins has changed. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. Recommended No action is required. Respond to this message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 222
Current value is . Probable Cause Indicates that the number of fabric logins has fallen below the low boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. A low number of fabric logins means that the fabric is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 223
fallen below the low boundary. SFP state changes occur when the SFP is inserted or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 224
failures that the port experiences has fallen problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 225
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot that the port experiences has troubleshoot your host bus adaptor (HBA) and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 226
Probable Cause Indicates that the number of synchronization losses that the port experiences has fallen below the low boundary. Loss of synchronization experience loss-of-synchronization errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity WARNING FW- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 227
of signal losses that the port experiences has changed. Loss of signal generally indicates a physical problem. Recommended Check both ends of that the switch is functioning normally. Severity INFO FW-1170 Message , [FW-1170], ,, WARNING, , , - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 228
Probable Cause Indicates that the number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended No - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 229
Low value>). Current value is . Probable Cause Indicates that the number of invalid words that the port experiences has changed. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. Recommended Check both ends of your connections, your - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 230
number of invalid words that the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 231
policy of the Action end-user installation. A low number of invalid CRCs means that the switch is functioning normally. Severity INFO FW-1182 Message , [FW-1182], ,, WARNING, , , , is above high boundary(High=, Low= - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 232
High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 233
(High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has risen above the high boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 234
(High=, Low=). Current value is . Probable Cause Indicates that the percentage of outgoing traffic that the port experiences has fallen below the low boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 235
, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 236
become an F_Port, has segmented, or has become a trunk port. Recommended No action is required. Respond to this message set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. A low level of invalid CRC errors means that the switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 237
also be caused by dirty equipment, temperature fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. Recommended No action is required. Respond to this message as is appropriate to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 238
the particular policy of the end-user installation. A low number of CRC errors means that the fabric is functioning normally. The CRC error area of the End-to-End Performance Monitor class helps you tune your fabric. To reduce CRC messages, experiment with alternative topologies and cabling schemes - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 239
=, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 240
High value>, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 241
value>, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has fallen below the low boundary. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 242
Low=). Current value is . Probable Cause Indicates that the number of frame types or commands that the port receives has fallen below the low boundary. The port has received a small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 243
Probable Cause Indicates that the number of frame types or commands that the port receives has changed from a value outside of the acceptable range to authorized to establish telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 244
The HTTP_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 245
The HTTP_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 246
policy (SNMP_POLICY) contains a list of internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 247
(IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended No action is required. Action Severity received from an unauthorized IP address. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 248
protocol write (WSNMP) violations has changed. WSNMP violations indicate that an SNMP "get/set" operation request has been received from an unauthorized IP address. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 249
) violations has risen above the high boundary. WSNMP violations indicate that an SNMP "get/set" operation request has been received from an unauthorized IP address. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 250
system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world-wide name (WWN). The SES_POLICY contains a list of WWNs of device ports that are allowed to access the SES Server functionality. Recommended Action Run the errShow command to determine the WWN of - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 251
violations indicate that an small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world-wide name of device ports that are allowed to access the Management Server functionality. Recommended Action Run the errShow command to determine the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 252
the number of serial violations has changed. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world-wide names (WWNs) for which serial port access is enabled. Recommended Action Run the errShow command to determine - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 253
risen above the high boundary. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world-wide names (WWNs) for which serial port access is enabled. Recommended Action Run the errShow command to determine the WWN of the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 254
that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch world-wide names (WWNs) for which front panel access is enabled. Recommended Action Run the errShow command to determine the WWN of the device that sent the request. Responses to security - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 255
been received. The FRONTPANEL_POLICY contains a list of switch world-wide names (WWNs) for which front panel switch tried to join the fabric. The SCC_POLICY contains a list of switches by world-wide name (WWN) that are allowed to be members of a fabric. Recommended Action Run the errShow command - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 256
private loop devices not performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 257
private loop devices not performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 258
the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies ensure that whenever a device login failure has been detected. Recommended Action Run the errShow command to determine the IP location of the login attempt. Responses - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 259
login failure has been detected. Recommended Action Run the errShow command to determine the IP location of the login attempt. Responses to downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 260
world-wide name (WWN). When the primary fabric configuration server (FCS) downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it rejects the packet - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 261
in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 262
in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 263
in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 264
in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 265
the low boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 266
the high boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 267
>, is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of switch link authentication protocol (SLAP) faulty packets has risen above the high boundary. This counter keeps track of the number of unexpected SLAP packets - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 268
is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has fallen below the low boundary. Recommended No action is required. Action Severity INFO FW-1366 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 269
Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value outside of the acceptable fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 270
finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 271
to a value within the acceptable range. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 272
that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 273
switch as well as one security command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 274
increases and decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended You might have to remove some unwanted files to create some flash space. Run the supportSave Action command to remove files from the kernel space. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 275
bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty power supply. Action Severity WARNING Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 276
absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the missing power supply. Action Severity WARNING FW - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 277
the number of faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are non-redundant. If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the micro-switch of the active CP before the heartbeat is up, this will cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 278
failures. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of blade failures is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty blade. Action Severity WARNING FW-1435 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 279
factor faulty ports: . (Port(s) . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty ports is greater than or equal to the policy set by the switchStatusPolicySet command. A port is considered - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 280
that the state of the specified field-replaceable unit (FRU) has changed to "inserted". This means that an FRU is inserted but not powered on. Recommended No action is required. Verify that the event was planned. Action Severity INFO FW-1442 Message , [FW-1442], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 281
values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch status is DOWN, 0 indicates no checking for switch status MARGINAL. The default values when an AP blade is or has been present - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 282
Probable Cause Indicates that mail alert overflow condition has occurred. Recommended Resolve or disable the mail alert using the fwMailCfg command. Action Severity WARNING FW-1501 Message , [FW-1501], ,, INFO, , Mail overflow cleared - - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 283
possible. Recommended Action Reboot the standby CP blade by ejecting the card and reseating it. If the problem persists, replace the standby CP. Severity or the switch errors. The switch processor reboots can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands. Some - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 284
28 HAM-1005 • Unknown • Fastboot • Giveup Master:SYSM • CP Faulty:SYSM • FirmwareDownload • ConfigDownload:MS • ChangeWWN:EM • Reboot:WebTool • Fastboot:WebTool • Software Fault:Software Watchdog • Software Fault:Kernel Panic • Software Fault:ASSERT • Reboot:SNMP • Fastboot:SNMP • Reboot • Chassis - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 285
28 HAM-1006 Recommended The standby CP will take over and reset the active CP.The system will be non-redundant as the Action standby becomes the active CP. Severity CRITICAL Fabric OS Message Reference 237 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 286
28 HAM-1006 238 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 287
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL HAMK to the active CP after 10 minutes, reboot the standby CP blade by ejecting the blade and reseating it. Severity INFO HAMK-1003 Message , [ - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 288
29 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 289
. Recommended Action Run the psShow command to verify the power supply status. Try to reseat the faulty fan field-replaceable unit (FRU) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 290
, and 4024 the entire switch must be replaced, because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 5000, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 291
, and 4024 the entire switch must be replaced, because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 292
the fan is faulty. Recommended Action Run the tempShow command to verify that the switch temperatures are within operational range. Refer to the hardware reference manual for the temperature range of your switch. Make sure that the area is well ventilated and that the room temperature is within - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 293
(in RPM) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000, or 48000. Recommended For the Brocade 4100, 4900, 7500, and AP7600, replace the fan field-replaceable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 294
-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 Message , [HIL-1302], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 295
30 HIL-1305 Severity ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fan(s) failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 296
have failed. This message is often preceded by a low fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 297
-1501 Message Probable Cause , [HIL-1501], ,, WARNING, , Slot , high temperature (). Indicates that the temperature of this blade has risen above the warning threshold. Fabric OS Message Reference 249 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 298
Recommended Action Run the fanShow command to verify all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 299
Recommended Action Run the fanShow command to verify all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 300
Action To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 301
. Replace any deteriorating fan field-replaceable units (FRUs). Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. Severity ERROR HIL-1602 Message , [HIL-1602], , FFDC - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 302
30 HIL-1602 254 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 303
HLO-1003], , FFDC, ERROR, , Invalid Hello received from port , Domain = , Remote Port =. Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the remote - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 304
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 305
. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 306
32 HMON-1001 258 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 307
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that information on PID, format refer to the Fabric OS Administrator's Action Guide. Severity INFO HTTP-1002 Message , [HTTP-1002], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 308
33 HTTP-1003 260 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 309
Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn commands. On the Action Brocade 7500 or 7600, switch off and on all primary power in order to power-cycle the unit - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 310
34 IBD-1001 262 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 311
-name>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to login. Action Severity WARNING Fabric OS Message Reference 263 53-1000437 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 312
35 IBPD-1003 264 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 313
Recommended Action Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. Severity ERROR ICPD-1002 Message < new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference for more information on this command. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 314
, , iSNS Client service is detected on multiple switches in fabric. Probable Cause Indicates that iSNS Client service is enabled on multiple switches in fabric. Recommended Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer Action to the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 315
36 ICPD-1008 ICPD-1008 Message , [ICPD-1008], ,, INFO, , iSCSI switch () is . Probable Cause Indicates that the iSCSI switch is reachable or unreachable. Recommended No action is required. Action Severity INFO Fabric OS Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 316
36 ICPD-1008 268 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 317
and prefix> Probable Cause Indicates that a change in local IP address has occurred. If the source of the address change is manual, this means that the address change was initiated by a user. If the source of the address change is the dynamic host configuration protocol (DHCP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 318
37 IPAD-1001 270 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 319
be a transient problem. Recommended Action If the message persists, check the memory usage on the switch, using the memShow command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 320
port>) tunnel ID() reason () Probable Cause Indicates that tunnel setup failed due to a configuration mismatch between the two ends. Reasons for such a mismatch could be the Compression, SACK, FastWrite, and TapePipelining setting. Recommended Change the tunnel configuration - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 321
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates that specified port has crashed. Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 322
39 ISCS-1000 274 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 323
/port /ge. Probable Cause Indicates that peering has started with the specified external internet storage name service service (iSNS) server is set to zero, so peering is disabled. Recommended If you wish to enable the iSNS server, use the isnscCfg command to show or set - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 324
Start re-register with external iSNS server slot/port /ge. Probable Cause Indicates that the re-register with the specified external internet storage name service (iSNS) server has started. Recommended No action is required. Action Severity INFO - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 325
with a valid slot/port. Refer to the appropriate hardware reference manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message Probable Cause Recommended Action , [ISNS-1011], ,, INFO, , iSNS Client Service is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 326
failure. Probable Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Verify the connection of the iSNS server to the slot/port. Use the isnscCfg command to display or Action correct the server IP address - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 327
SIGABRT is the signal thrown by the programs to abort the process. Run the supportSave command to determine, if any core files were created. If a core file is found, core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 279 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 328
41 KSWD-1003 280 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 329
Chapter KTRC System Messages 42 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Cause Indicates that the dump memory size has exceeded the dump file size. Recommended No action is required. Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 330
KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that Trace was unable to initialize. Recommended No action is required. Action Severity ERROR 282 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 331
. Recommended Action Run the reboot command for nonbladed switches or the haFailover command on bladed switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 332
43 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates that the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 284 Fabric OS Message Reference 53- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 333
valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 334
44 LSDB-1004 Recommended Run the switchDisable and switchEnable commands. A new local link state record is generated Action during the switch enable. Severity CRITICAL LSDB-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 335
or an haFailover (if applicable). If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], ,, INFO, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 336
purposes only, and no action is required. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode checkbox. The switch must be disabled to change the IDID mode. Severity WARNING 288 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 337
Chapter MPTH System Messages 46 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates that a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 338
46 MPTH-1003 290 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 339
MSG_INTR • 4 - MSG_STR • 6 - MSG_ASYNC_IU • 7 - MSG_LINIT_IU • 8 - MSG_RSCN • 9 - MSG_IOCTL • 10 - MSG_ACCEPT • 11 - MSG_IU_FREE • 12 - MSG_US • 13 - MSG_EXT_RSCN • 14 - MSG_RDTS_START • 15 - MSG_RDTS_SENDEFP • 16 - MSG_RDTS_RESET Recommended No action is required. Action Severity ERROR Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 340
47 MQ-1004 292 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 341
for GCAP from> The switch did not respond to a request for GCAP (MS Get Capabilities) command. Recommended Action: No action is required. • The GCAP (MS Get Capabilities) is supported but the flag for MS platform service is not set. Recommended Action: Set the flag for the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 342
48 MS-1003 • Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • Wait a few minutes and try the command again. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 343
minutes and try the operation again. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], ,, ERROR, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 344
INIT phase of a reboot. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR MS-1022 Message , [MS-1022], ,, INFO, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 345
48 MS-1023 MS-1023 Message , [MS-1023], ,, INFO, , Management Server Topology Discovery Service Probable Cause Indicates that Management Server Topology Discovery Service is being enabled or disabled. Recommended No action is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 346
48 MS-1024 298 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 347
Wait • 5 - Full If this error occurs repeatedly, it means the protocol implementation between two connected switches has problems. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 348
>,, WARNING, , DB_XMIT_SET flag not set in state , input , port Probable Cause Indicates that the database transmit set flag was not set for the specified input state on the specified port. Neighbor finite state machine (NBFSM) states are - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 349
>, [NS-1001], ,, WARNING, , The response for request 0x from remote switch 0x is larger than the max frame size the remote switch can support! Probable Cause Indicates that the response payload exceeds the maximum frame size that the remote - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 350
the standby CP has lower supported capability than the active CP due to different firmware versions running on the active and standby CPs. This means that the active and standby CPs are out of sync. Any execution of the haFailover or firmwareDownload commands will be disruptive. Recommended Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 351
) process. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 352
(FSS). Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1006 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 353
the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1009 Message , [PDM-1009], ,, WARNING, , Can't update Port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 354
file. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1012 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 355
command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service >,, WARNING, , Failed to download area port map. Fabric OS Message Reference 307 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 356
is not supported by older firmware. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 357
51 PDM-1024 Fabric OS Message Reference 309 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 358
51 PDM-1024 310 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 359
trap generated. The watchdog register codes are as follows: • 0x10000000 bit set means that the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved. Recommended Run the pdShow command to view the panic dump and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 360
52 PDTR-1002 312 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 361
. If the system does not reboot, then try issuing the reboot command from a command-line prompt. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL PLAT-1001 Message , [PLAT-1001 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 362
53 PLAT-1001 314 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 363
> Faulted because of many Link Failures Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple failures that exceed an internally set threshold on the port. This problem is typically related to hardware. Recommended Action Check and replace (if - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 364
portCfgLport to clear configuration. Probable Cause Indicates that the specified port is configured to be an L_port, but that port does not support L_port. If an L_port is connected, then the port will be disabled because it does not support L_port. If an E_port or F_port is connected then the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 365
automatically. If it does not, reboot or power cycle the switch to Action reinitiate the firmware. Severity CRITICAL PS-1001 Message , Recommended No action is required. Refer to the Fabric OS Administrator's Guide for more information about the Action PID format. Severity INFO PS- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 366
Probable Cause Indicates that the restoring configuration has attempted to set the end-to-end monitoring mask on at least one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring can only be disabled - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 367
to destination port> are swapped. New area for port is and port is . Probable Cause Indicates that the portSwap command has been - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 368
56 PSWP-1003 320 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 369
) to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. MB) was reached. Probable Cause Indicates that the maximum storage size for FFDC data capture is reached. Recommended Run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 370
, Software 'verify' error detected. Probable Cause Indicates a internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1005 Message , [RAS-1005], , FFDC, WARNING, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 371
, v4.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 372
firmwareDownload command to upgrade the firmware for any switches that do not support RCS. code>. Probable Cause Indicates that a receiving switch is rejecting an RCS phase. Recommended Action If the reject is in ACA phase, wait several minutes and then retry the operation from the sender switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 373
returned 0x. Probable Cause Indicates that a remote domain rejected an RCS phase initiated by an application on the local switch. If the reject DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 374
58 RCS-1008 326 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 375
-name>, Permission denied accessing certificate file. Secure RPCd is disabled. Probable Cause Indicates that the SSL certificate file configured on the switch could not be accessed because root did not have read-level access. Recommended Change the file system access level for the certificate - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 376
that the private key file is missing. Recommended Run the pkiCreate command to install a valid private key file. Action Severity WARNING RPCD- disabled. Probable Cause Indicates that the private key file configured on the switch could not be accessed because root did not have read-level access. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 377
if the specified domain ID is online. Enable the switch with the specified domain ID. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 329 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 378
and retried. Recommended Action Run the dom command to verify that the specified domain ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 330 Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 379
61 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 380
61 SAS-1001 332 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 381
watchdog will cause the daemon to dump the core and reboot the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 333 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 382
62 SCN-1001 334 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 383
code> Probable Cause Indicates that the reliable commit service (RCS) process fails to complete. RCS is a mechanism for transferring data from one switch to other switches needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 384
If the message is the result of a user command, retry the statistic command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING 336 Fabric OS Message Reference 53 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 385
was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the HTTP connection. Action Severity INFO SEC-1009 Message , [SEC-1009], ,, INFO, , Security violation - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 386
). Recommended Action Run the pkiShow command and verify that all public key infrastructure (PKI) objects exist on the switch. If the private key does not exist, follow the steps for re-creating PKI objects, outlined in the Secure Fabric OS Administrator's Guide. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 387
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 388
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the sync. Probable Cause Indicates that the security database size is not supported by the standby control processor (CP). Recommended Reduce the security - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 389
in the secPolicyAdd command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch connection control - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 390
Cause Indicates that the world-wide name (WWN) entered in the policy member list had an invalid format. Recommended Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight Action colon separated pairs. For example: 50:06:04:81:D6:F3:45:42. Severity ERROR - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 391
[SEC-1042], ,, ERROR, , Invalid index/area member in portlist (). Out of range ( - ). Probable Cause Indicates that the specified index or area member is not within the minimum and maximum range. Recommended Use - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 392
[SEC-1045], ,, ERROR, , Too many port members. Probable Cause Indicates that there has been a corruption during the Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 393
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 394
], ,, ERROR, , Missing brace for port list . Probable Cause Indicates that there has been a corruption during Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 395
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 396
.,> to flash. Probable Cause Indicates that the operation failed when writing to flash. Recommended Run the supportFtp - e command to FTP files from the switch and remove them from the flash. Action Severity ERROR SEC-1062 Message , [SEC-1062], ,, ERROR - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 397
Cause Indicates that the security database is corrupted for unknown reasons. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity ERROR Fabric OS Message Reference 349 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 398
The security database is corrupted for unknown reasons. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], ,, ERROR - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 399
perform the operation in non-secure mode. In secure mode, run the command from a switch that has required privilege, that is, either a backup FCS or primary ERROR, , Fail to new policy set on all switches. Probable Cause Indicates that there has been a corruption during - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 400
to activate new policy set on all switches. Probable Cause Indicates that the policy could not be activated. Possible reasons that the policy could not be activate include not enough memory or a busy switch. Recommended Run the secFabricShow command to verify that all switches in the fabric are - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 401
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 402
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 403
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 404
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 405
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 406
Indicates that the specified policy could not be found. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR 358 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 407
that the specified policy could not be found. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity ERROR SEC-1099 Message , [SEC-1099], ,, ERROR, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 408
command to verify that all switches in the fabric are in the ready state. When all switches switch failed to download certificate, security database, or policies. This can happen when switch Probable Cause Indicates that the switch failed to get either the that the primary switch has a valid - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 409
to verify that all switches in the fabric are in the ready state. Retry the Action command when all switches are READY. Severity ERROR switch. If a failure to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 410
Verify that the security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry the operation. Severity ERROR SEC-1110 Message , [SEC-1110 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 411
no primary fabric configurations server (FCS) is present in the fabric. Recommended Run the secFabricShow command to verify that all switches in fabric are in the ready state. When Action all switches are in the ready state, retry the operation. Severity ERROR SEC-1116 Message , [SEC - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 412
Recommended Run the secFabricShow command to verify that all switches in fabric are in the ready state. When Action all switches are in the ready to set SNMP string. Probable Cause Indicates that the SNMP string could not be set. Recommended Usually this problem is transient. Retry the command. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 413
>,, INFO, , Error code: , . Probable Cause Indicates that one of the switches in the fabric could not communicate with the primary fabric configurations server (FCS). Recommended Run the secFabricShow command to verify that all switches in fabric are in the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 414
INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Indicates that an FCS failover operation was completed successfully. Recommended Action Verify that the security event was planned. If the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 415
time service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 416
time service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 417
support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 418
modifying the index/area ID. The status values can be either defined, active, or both. A negative value means that a policy set was failed command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 419
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 420
option was attempted while the fabric is already in secure mode. Recommended Do not use the lockdown option with the secModeEnable command when switch is already in Action secure mode. Severity ERROR SEC-1164 Message , [SEC-1164], ,, ERROR, , Lockdown - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 421
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 422
to check if all PKI objects exist. If they do not exit, run the pkiCreate command to create them for the switch. Run the licenseAdd command to install the required license key. Refer to your switch supplier to obtain a license if you do not have one. Severity ERROR SEC-1172 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 423
password. Probable Cause Indicates that the FCS or non-FCS password could not be set. Recommended Verify that all switches in the fabric are in time synchronization with the primary and that no Action external entity is trying to access the fabric. When verification is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 424
because of an invalid value. Recommended Action Retry the command with a valid value. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR 376 Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 425
. Probable Cause Indicates that the switch database was enabled or disabled as the secondary authentication, accounting, and authorization (AAA) mechanism when the remote authentication dial-in user service (RADIUS) is the primary AAA mechanism. Recommended No action is required. Action Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 426
,, INFO, , Security violation: Unauthorized device tries to FLOGI to index/area of switch . Probable Cause Indicates that a device connection control (DCC) security violation was reported. The specified device attempted to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 427
-1192 Message , [SEC-1192], ,, INFO, , Security violation: Login failure attempt via . Probable Cause Indicates that a serial or modem login security violation was reported. An incorrect password was used while trying to log in through - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 428
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 429
all default account names. Probable Cause Indicates that the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default admin and user account names on the switch that reported the warning and retry Action enabling security. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 430
violation: Unauthorized access to serial port of switch . Probable Cause Indicates that a serial connection policy security violation was , , Security violation: MS command is forwarded from non-primary FCS switch. Probable Cause Indicates that a management server - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 431
from MS device node name , device port name . Probable Cause Indicates that a management server (MS) command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 432
run the supportSave command and contact your switch service provider. Severity ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Probable Cause Indicates that the switch is set up with VC-encoded - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 433
installed software version does not support the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify that the firmware you are installing supports the Brocade Secure Fabric OS feature - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 434
. Recommended Action Run the pkiShow command and verify that all public key infrastructure (PKI) objects exist on the switch. If a failure to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. If PKI objects are valid - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 435
the specified remote authentication dial-in user service (RADIUS) server responded to a switch request. Recommended If the message appears frequently, move the responding server to the top of the RADIUS server Action configuration list using the aaaConfig command. Severity INFO SEC-1308 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 436
the default value. Recommended Action Verify that the security event was planned. If the security event was planned, run the passwdCfg --setDefault command on each switch in the fabric to set the password policies to the default value. Then verify with passwdCfg --show that password policies are - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 437
the system to fix this error. If the problem persists contact your switch service Action provider. Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command failed - db(s) configured - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 438
, , Non-acl domain tries to join a fabric with strict fabric wide policy Probable Cause Indicates that a domain not supporting an access control list (ACL) policy tried to join a fabric with a strict fabric-wide policy. Recommended No action is required. The domain is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 439
command. Severity ERROR SEC-1322 Message , [SEC-1322], ,, WARNING, , Some DCC policy is too large, distribution cancelled Probable Cause Indicates that this fabric is not able to support a device connection control (DCC) policy with more than 256 ports - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 440
error: Probable Cause Indicates that the reliable commit service (RCS) transaction failed with specified reason code. Recommended Verify that number>,, ERROR, , Security enforcement: Switch connecting to port is not authorized to stay in fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 441
disallowing all its E-ports connected to the code>. Probable Cause Indicates that the IP filter policy enforcement failed due to internal system failure. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 442
Attempt to enable secure mode failed. Reason: . Probable Cause Indicates that the secModeEnable command failed on the fabric, because default IP Filter policies are not active on the switch, or an active transaction exists on IP Filter policies. Recommended Action Verify that the security - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 443
Ethernet and Fibre Channel interface is set correctly. If the Action specified Reason is an initialization failure, the switch requires a reboot. Severity ERROR SNMP (SNMP) service failed and you will not be able to query the switch through SNMP. Recommended Reboot or power cycle the switch. This - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 444
64 SNMP-1004 SNMP-1004 Message , [SNMP-1004], , FFDC, ERROR, , Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration is incorrect and the SNMP service snmpConfig --show command to see the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 445
Probable Cause Indicates that the supportSave command was used to transfer support information to a remote FTP command. Recommended Check the FTP server and settings. Run the supportFtp command to set the FTP parameters. After Action the FTP problem is corrected, rerun the supportSave command - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 446
65 SS-1001 398 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 447
17 minutes. The process is set to time out after 30 minutes. Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue without disruption. Do not fail over or power down the system during firmware upgrade. No action is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 448
standby has now become the active CP and is running the new firmware version. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. Severity INFO SULB-1007 Message , [SULB-1007 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 449
SULB-1009], AUDIT, INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates that the firmwareDownload command failed. The additional status code and error code provide debugging information. Table lists - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 450
was an unexpected reboot during firmwareDownload. The command is aborted." "Standby CP was not responding. The command is aborted." "firmwareCommit has started on both CPs. Please use firmwareDownloadStatus and firmwareShow to see the firmware status." Status Code 0x65 0x66 0x67 0x68 0x69 0x6a 0x6b - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 451
the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab "Blade failed to reboot with the original image. firmwareRestore command failed." 0xac Fabric OS Message Reference 403 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 452
command to correct the inconsistency 0x11 before proceeding. For example: swap OSRootPartitions and reboot." "Unable to access the required package list file. Check whether the switch is supported by the requested firmware restore the original firmware, or contact your service provider for recovery - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 453
Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power off these blades before - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 454
Upgrade State and Code Value Upgrade State Code SUS_PEER_CHECK_SANITY SUS_PEER_FWDL_BEGIN SUS_SBY_FWDL_BEGIN command for more information. In a director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 455
state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1018 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 456
state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 457
of the firmwareDownload command, for example, by powering off and on of the indicated BP blade in the middle firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 458
firmwareDownloadStatus Action command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message , [SULB-1031], , AUDIT, WARNING, , The switch is relocating an internal firmware image. Probable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 459
problem persists, contact your switch service firmware to store version information. Recommended No action is required. Action Severity INFO SULB-1037 Message , [SULB-1037], , AUDIT, INFO, , HCL failed. Reboot the switch manually using the reboot command - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 460
66 SULB-1037 Probable Cause Many reasons can cause HCL to fail, such as domain not confirmed Recommended Run the reBoot command to reboot the switch manually. Action Severity Error 412 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 461
needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 462
a blade has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 463
Cause Indicates that the blade is enabled with the port configuration that already has area swapped. Recommended Action Replace the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide for more information on - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 464
67 SWCH-1008 416 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 465
might be a conflict between the two versions of firmware or the nonvolatile storage might be corrupted. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSC-1002 Message , [SYSC - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 466
from the chassis option storage device> is not supported by CP Blade with ID . Brocade 24000 and 48000. Recommended Action As indicated in the message, run the chassisConfig command to change to one that is valid on this platform running this firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 467
memory. Recommended Action Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 468
is properly seated in its slot. Action Severity CRITICAL SYSM-1006 Message , [SYSM-1006], , FFDC, CRITICAL, , CP blade in slot is incompatible with the chassis type. Probable Cause Indicates that this chassis type is not compatible with the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 469
WATCHDOG EXPIRED generated by hardware watchdog expiration • MANUAL generated by the tracedump -n command Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity WARNING TRCE-1002 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 470
, or network down. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR TRCE-1004 Message , [TRCE-1004], ,, WARNING, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 471
to the Brocade 24000, and 48000. Recommended Action This message is often transitory. Wait a few minutes and try the command again. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 472
Brocade 24000 and 48000. Recommended Action Run the haShow command to verify that the current CP is standby and the active CP is active. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 473
system and the indicated slot is unavailable. Recommended Check that the AP blade is enabled and retry the command. If the AP blade is already enabled, run Action the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 425 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 474
70 TRCE-1012 426 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 475
message indicates a typing error by an authorized user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed login is reported to the error log. Severity INFO TRCK-1003 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 476
the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration only task possible. Recommended No action is required. Run the configShow command to view the configuration file. Action Severity INFO TRCK-1005 Message < - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 477
>,, WARNING, , NTP Query failed: Probable Cause Indicates that a network time protocol (NTP) support the feature. If the message does not recur, it should be ignored. Recommended Action Run the tsClockServer command to verify that the principal or primary FCS switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 478
might be one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits. • Synchronizing , , Probable Cause Indicates that a switch is trying to set the tsclockserver, which is not the primary fabric configuration server - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 479
Cause Indicates that there is a change in the source of fabric time synchronization distributed from the principal or primary fabric configuration server (FCS) switch. Another clock server in the list of clock servers configured is being used. This happens when the network time protocol (NTP) query - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 480
72 TS-1008 432 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 481
Action database. Run the uRouteShow command to display the new routing tables. Severity CRITICAL UCST-1020 Message , [UCST-1020], ,, WARNING, , Static route (input-area: , domain: output-area: ) has been ignored due - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 482
73 UCST-1020 434 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 483
, [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates that the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended No action is required - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 484
74 UPTH-1001 436 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 485
to disable HTTPS. Install a valid key file and enable HTTPS again. For Action more information on the configure command, refer to the Fabric OS Command Reference. Severity WARNING WEBD-1003 Message , [WEBD-1003], ,, INFO, , HTTP/HTTPS interface disabled - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 486
>, FFDC, INFO, , HTTP server will be restarted due to change of IP Address Probable Cause Indicates that the IP address of the switch changed and the HTTP server is restarted. Recommended No action is required. Action Severity INFO 438 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 487
the built-in recovery process has failed to restore http services. The problem often results from invalid configuration of ssl certs., but there can be more than one reason for such failure. Recommended Run the configure command and disable/enable http or https. Action Severity WARNING Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 488
75 WEBD-1008 440 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 489
files of the related modules (zoned, nsd, rcsd). If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 441 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 490
76 ZOLB-1001 442 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 491
string>) at port() Probable problems when adding content-addressable memory (CAM) entries before the filter setup. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 492
is zoned using both world-wide name (WWN) in one zone and in another, this will cause that port to go session based hard zoning. In session-based zoning, the zone enforcement is checked by the software. In hardware-enforced zoning, zone or alias members are defined using - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 493
name>, Ioctl() in () at port () returns code () and reason string ( - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 494
-name>, WARNING All ports are offline. Probable Cause Indicates that all the ports in a zone are supported. Probable Cause Indicates that the QuickLoop feature is not supported in the current code release. If the QuickLoop zoning configuration is enabled on the switch, it will not be supported - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 495
license is missing. Recommended Install the zoning license using the licenseAdd command. Refer to your switch supplier to obtain a Action Zoning license if you do not zone database to ensure that only one initiator is set for each FA zone configuration. Action Severity ERROR Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 496
based hard zoning (value = 3) • FA zone (value = 5) QuickLoop zones are not supported in Fabric OS v4.x and above. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 497
operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 498
, edit the zoning database to have zoned PIDs for that Action port. Severity INFO ZONE-1027 Message , [ZONE-1027], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 499
the zoned core file directory. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message , [ZONE-1030], ,, WARNING, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 500
Recommended Action Severity , [ZONE-1031], ,, ERROR, , Switch is in interop mode. (switch, port) members not supported. The switch is set to interop mode using the interopMode command. Interop mode does not allow members in the active zone - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 501
zone database is not found. Recommended Use the firmwareDownload command to reinstall the firmware. Action Severity WARNING ZONE-1035 Message , [ the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 502
the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 503
too large for the memory available on the switch. Recommended Reduce the size of the zone database >, Unstable link detected during merge at port (). Probable Cause Indicates a possible mode is set to No Access. Probable Cause Indicates that the Default Zone access mode is set to No - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 504
-1044 Message , [ZONE-1044], ,, INFO, , The Default Zone access mode is set to All Access. Probable Cause Indicates that the Default Zone access mode is set to All Access. Recommended Verify that this Default Zone access mode change was done intentionally - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 505
to []. Probable Cause Indicates that an authentication configuration value was set to a specified value. The data type is "authentication type", "DH the secret database operation has been updated using the secAuthSecret command. Recommended No action is required. Action Severity INFO - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 506
-handshake authentication protocol (DH-CHAP) failed on the specified port due to mismatched response values between two entities. The error commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 507
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , [AUTH-3008], INFO, SECURITY, , , , Event: , Status: failed, Info: Port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 508
78 AUTH-3008 460 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 509
system attempted to download a configuration without disabling the switch was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch using the switchDisable command and download the configuration. Action Severity WARNING Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 510
79 CONF-1022 462 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 511
Chapter AUDIT HTTP System Messages 80 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 512
80 HTTP-1003 464 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 513
Chapter AUDIT SEC System Messages 81 SEC-3001 Message AUDIT, , [SEC-3001], INFO, SECURITY, , , , Event: , Status: success, Info: Security mode on the fabric. Probable Cause Indicates that the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 514
81 SEC-3003 SEC-3003 Message AUDIT, , [SEC-3003], INFO, SECURITY, , , , Event: , Status: success, Info: Created policy, with member(s) . Probable Cause Indicates that a new security policy was created - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 515
81 SEC-3006 SEC-3006 Message AUDIT, , [SEC-3006], INFO, SECURITY, , , , Event: , Status: success, Info: Removed member(s) from policy . Probable Cause Indicates that a user has removed the specific - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 516
81 SEC-3009 SEC-3009 Message AUDIT, , [SEC-3009], INFO, SECURITY, , , , Event: , Status: success, Info: Security Transaction aborted. Probable Cause Indicates that the pending security transaction was aborted. Recommended Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 517
location>, , Event: , Status: success, Info: Temp Passwd on domain [] for account []. Probable Cause for AAA services. Probable Cause Indicates that a user has changed the remote authentication dial-in user service (RADIUS) configuration - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 518
name> to position . Probable Cause Indicates that a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify that the RADIUS server position was intentionally changed. If the RADIUS server position was intentionally - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 519
SECURITY, , , , Event: , Status: success, Info: Passwdcfg parameters set to default values. Probable Cause Indicates that the passwdCfg parameters are set to default values. Recommended Action Verify that the security event was planned. If the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 520
password attempts exceeded, the account has been locked. Recommended The Account may automatically unlock after the lockout duration has expired or an administrator Action may manually unlock the account. Severity INFO 472 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 521
81 SEC-3024 SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Probable Cause Indicates that the user's password changed. Recommended Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 522
81 SEC-3027 SEC-3027 Message AUDIT, , [SEC-3027], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] []. Probable Cause Indicates that user account properties were changed. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 523
SEC-3032 Message AUDIT, , [SEC-3032], INFO, SECURITY, , , , Event: , Status: success, Info: Switch is configured to database. Probable Cause Indicates that the specified event has occurred to accept - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 524
-3033], INFO, SECURITY, , , , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to . Probable Cause Indicates that the specified event has occurred. Recommended Verify that the event was - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 525
was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action as defined by your enterprise security policy. Severity INFO Fabric OS Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 526
81 SEC-3039 478 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 527
protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration and new values for that parameter. Recommended Execute the snmpConfig --show command to display the new configuration. Action Severity INFO SNMP-1006 Message AUDIT - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 528
82 SNMP-1006 480 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 529
. The process is set to time out after 30 minutes. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 530
timestamp>, [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates that the firmwareDownload command failed. The additional status code and error code provide debugging information. Table - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 531
was an unexpected reboot during firmwareDownload. The command is aborted." "Standby CP was not responding. The command is aborted." "firmwareCommit has started on both CPs. Please use firmwareDownloadStatus and firmwareShow to see the firmware status." Status Code 0x65 0x66 0x67 0x68 0x69 0x6a 0x6b - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 532
the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab "Blade failed to reboot with the original image. firmwareRestore command failed." 0xac 484 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 533
command to correct the inconsistency 0x11 before proceeding. For example: swap OSRootPartitions and reboot." "Unable to access the required package list file. Check whether the switch is supported by the requested firmware restore the original firmware, or contact your service provider for recovery - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 534
Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power off these blades before - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 535
Upgrade State and Code Value Upgrade State Code SUS_PEER_CHECK_SANITY SUS_PEER_FWDL_BEGIN SUS_SBY_FWDL_BEGIN command for more information. In a director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 536
state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1018 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 537
of the firmwareDownload command, for example, by powering off and on of the indicated BP blade in the middle firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 538
will continue after the switch has rebooted. Run the firmwareDownloadStatus Action command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1031], WARNING, FIRMWARE, , - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 539
again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However, it will - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 540
83 SULB-1037 Severity Error 492 Fabric OS Message Reference 53-1000437-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 541
-details>, , , Event: , Status: success, Info: \"\" added to \"\". Probable Cause Indicates that a new zone object member or members have been added to the specified zone object - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 542
event-location>, , Event: , Status: success, Info: \"\" removed from \"\". Probable Cause Indicates that the specified zone object member or members have been removed from the specified zone object - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 543
84 ZONE-3006 ZONE-3006 Message AUDIT, , [ZONE-3006], INFO, ZONE, , , , Event: , Status: success, Info: Current zone configuration disabled. . Probable Cause Indicates that the current zone configuration has been disabled. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 544
84 ZONE-3009 ZONE-3009 Message AUDIT, , [ZONE-3009], INFO, ZONE, , , , Event: , Status: success, Info: . Probable Cause Indicates that the specified zone transaction has been aborted. Recommended Verify that the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 545
Probable Cause Indicates that the specified new admin domain (AD) object member or members have been added to the specified AD object set. An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in the message. Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 546
>\" created with \"\". Probable Cause Indicates that the specified admin domain (AD) has been created. An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in the message. Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 547
, FABRIC, , , , Event: , Status: success, Info: \"\" removed from \"\". Probable Cause Indicates that the specified admin domain (AD) member or members have been removed from an AD - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 548
84 ZONE-3021 ZONE-3021 Message AUDIT, , [ZONE-3021], INFO, FABRIC, , , , Event: , Status: success, Info: AD object \"\" renamed to \"\". Probable Cause Indicates that the specified admin domain ( - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 549
enterprise security policy. Severity INFO ZONE-3025 Message AUDIT, , [ZONE-3025], INFO, FABRIC, , , , Command: Info: executed. In AD . Probable Cause Indicates that the admin domain ad --exec operation was executed in the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference - Supporting Fabric O - Page 550
84 ZONE-3025 502 Fabric OS Message Reference 53-1000437-01
53-1000437-01
15 June 2007
Fabric OS
Message Reference