3Ware 7000-2 User Guide - Page 57

3Ware 7000-2 - Escalade RAID Controller Manual

Page 57 highlights

3ware Disk Array Configuration Utility array. If the verify array process determines that the mirrored drives are not identical or the parity is not correct, the array is degraded and the rebuild process is launched. Maintain Disk Array The array listed below can have its write cache state changed. Verify checks the data integrity of a fault tolerant array. Array Unit 2 - 2 drive Mirror Port 2 - QUANTUM FIREBALLP LM30 Port 3 - QUANTUM FIREBALLP LM30 30.0GB 30.0GB 30.0GB Array's Write Cache State: Verify Array: enabled no OK Cancel Alt-F1 Help Previous/Next Enter Change Value Esc Cancel Figure 16. Maintain Disk Array Display Note: Fault tolerant arrays can not be verified until after they are initialized. For RAID 1 and 10 arrays the initial verify must first be done in 3DM, otherwise the initialization will not be done. Rebuilding a mirrored disk array Escalade ATA RAID Controllers allow you to create fault tolerant disk arrays by selecting a mirrored RAID 1 or RAID 10 array. These disk arrays store identical data on two or more drives to protect against drive failure. If one or more of the drives of a mirrored www.3ware.com 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

3ware Disk Array Configuration Utility
www.3ware.com
57
array. If the verify array process determines that the mirrored drives
are not identical or the parity is not correct, the array is degraded
and the rebuild process is launched.
Figure 16.
Maintain Disk Array Display
Note:
Fault tolerant arrays can not be verified until
after they are initialized. For RAID 1 and 10 arrays the
initial verify must first be done in 3DM, otherwise the
initialization will not be done.
Rebuilding a mirrored disk array
Escalade ATA RAID Controllers allow you to create fault tolerant
disk arrays by selecting a mirrored RAID 1 or RAID 10 array.
These disk arrays store identical data on two or more drives to pro-
tect against drive failure. If one or more of the drives of a mirrored
Maintain Disk Array
enabled
no
Cancel
OK
The array listed below can have its write cache state changed.
Verify checks the data integrity of a fault tolerant array.
Array Unit 2 - 2 drive Mirror
30.0GB
Port 2
- QUANTUM FIREBALLP LM30
30.0GB
Port 3
- QUANTUM FIREBALLP LM30
30.0GB
Array's Write Cache State:
Verify Array:
Help
Alt-F1
Change Value
Enter
Previous/Next
Cancel