Dell DX6000G Hardware Owner's Manual - Page 25
CPU Bus parity, Power Supply
View all Dell DX6000G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Table 1-1. LCD Status Messages (continued) Code E1420 E1422 E1610 E1614 E1618 E161C Text Causes Corrective Actions CPU Bus parity The system BIOS has error. Power reported a processor bus cycle AC. parity error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. CPU # machine check error. Power cycle AC. The system BIOS has reported a machine check error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. Power Supply # (### W) missing. Check power supply. Specified power supply was removed or is missing from the system. See "Troubleshooting Power Supplies" on page 147. Power Supply # (### W) error. Check power supply. Specified power supply has failed. See "Troubleshooting Power Supplies" on page 147. Predictive failure on Power Supply # (### W). Check PSU. An over-temperature condition or power supply communication error has caused the predictive warning of an impending power supply failure. See "Troubleshooting Power Supplies" on page 147. Power Supply # (### W) lost AC power. Check PSU cables. Specified power supply is attached to the system, but it has lost its AC input. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 147. About Your System 25