Dell DX6000G Hardware Owner's Manual - Page 50
Warning! No micro, Check PSU.
View all Dell DX6000G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Table 1-2. System Messages (continued) Message Causes Corrective Actions Warning! No micro Micro code update failed. code update loaded for processor n Update the BIOS firmware. See "Getting Help" on page 169. Warning! Power required exceeds PSU wattage. Check PSU and system configuration. Warning! Performance degraded. CPU and memory set to minimum frequencies to meet PSU wattage. System will reboot. The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with the High Output power supplies to use the components. See "Power Supplies" on page 86. Warning! PSU mismatch. PSU redundancy lost. Check PSU. A High Output power supply Install two High Output or and an Energy Smart power two Energy Smart power supply are installed in the supplies in the system. system at the same time. You can also run the system on one power supply until you can obtain two power supplies of the same type. See "Troubleshooting Power Supplies" on page 147. 50 About Your System