Dell DX6000G Hardware Owner's Manual - Page 28
SAS cable B
View all Dell DX6000G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-1. LCD Status Messages (continued) Code E1810 E1812 E1920 E1A14 E1A15 E1A1D E2010 Text Causes Hard drive ## The specified hard drive fault. Review has experienced a fault. & clear SEL. Hard drive ## The specified hard removed. Check drive has been removed drive. from the system. iDRAC6 Upgrade Optional iDRAC6 Failed. upgrade has failed. SAS cable A SAS cable A is missing failure. Check or bad. connection. SAS cable B SAS cable B is missing failure. Check or bad. connection. Control panel USB cable not detected. Check cable. USB cable to the control panel is missing or bad. Memory not No memory was detected detected. in the system. Inspect DIMMs. Corrective Actions See "Troubleshooting a Hard Drive" on page 152. Information only. See "Troubleshooting Expansion Cards" on page 155. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 169. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 169. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 169. Install memory or reseat memory modules. See "Installing Memory Modules" on page 115 or "Troubleshooting System Memory" on page 148. 28 About Your System