Epson C3500 Technical Reference Guide - Page 101
Printing method, GS1 DataBar Expanded
View all Epson C3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Chapter 3 Handling GS1 DataBar Expanded ❏ Specify the data of 2 to 255 digits. ❏ '()' is the delimiter for the application identifiers. (printed as the HRI character, but not encoded.) ❏ Be sure to include all the application identifiers in the data. ❏ When the first data is '01' after deleting application identifiers, left and right parenthesis, and '*' from the specified data, the 14th digit from the next of '01' is checked as a check digit. When it is not correct, an error occurs. ❏ When the next data of '01' is fewer than 14 digits, a check digit is not checked. (Unlike GS1-128, the check digit is not automatically calculated, nor replaced with '*.' When '*' is specified, '*' is ignored, and the rest of the data is shifted by 1 digit.) ❏ Specify the special character using the following format. Control Character ASCII HRI Character FNC1 {1 Space is printed. Left parenthesis for the application identifier ( '(' is printed. Right parenthesis for the application identifier ) ')' is printed. 3 '*' {* Error Skipped character * Not printed. Printing method Specify the selected barcode font, specified point and language to the printing data, and then print it. The font size of the barcode can not be changed by [Specified Point] value. The barcode is not printed when other values are selected. 101