GS1-128M, Control Character, ASCII, HRI Character, Format Identifier, Format
View all Epson C3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Chapter 3 Handling GS1-128M ❏ Specify the data of 38 to 66 digits. ❏ '()' is the delimiter for the application identifiers. (printed as the HRI character, but not encoded.) ❏ The start codes (CODE A, CODE B, CODE C) and the stop code are added automatically. ❏ A symbol character FNC1, which is described after the start code, is automatically added. ❏ When FNC1 is not at the end of the data followed by the application identifier '(30)', FNC1 is automatically added. ❏ FNC1 must not be at the end of the data followed by the application identifier '(10)' or '(21)'. In this case, an error occurs. ❏ When '(01)' is specified as the application identifier, the 14th digit becomes a check digit, however, it is not proved when the check digit is specified. When the 14th digit is '*,' the check digit is automatically calculated, and replaced with '*.' ❏ When the character right after '{' is not '1', an error occurs. ❏ Specify the special character as the following format. Control Character ASCII HRI Character 3 FNC1 {1 Space is printed. Left parenthesis for the application identifier ( '(' is printed. Right parenthesis for the application identifier ) ')' is printed. Check digit position * Check digit is printed. ❏ An error occurs when the format identifiers do not meet the following condition. Format Identifier Format 01 Numbers of 14 digits 10 Alphanumerics of 1 ~ 20 digits 17 Numbers of 6 digits (YYMMDD) 21 Alphanumerics of 1 ~ 20 digits 30 Numbers of 1 ~ 8 digits 99