HP Scitex FB10000 Site Preparation Guide Rev. 2 - Page 17

Pneumatic and Extraction Requirements, Environmental Requirements, Hz: 3-phase 480 V, 400 V or

Page 17 highlights

Table 2-1 Summary of Site Preparation Specifications Site protection (amperage) • 50 Hz: Printing unit: 75A, UV system: 90 A • 60 Hz: Printing unit: 75A, UV system: 80 A See Electrical Requirements on page 28. Voltages • 50 Hz: 3-phase 400 V (-5% /+10%) • 60 Hz: 3-phase 480 V, 400 V or 208 V (-5% /+10%) See Electrical Requirements on page 28. Voltage spikes +5% or -10% See Power Line Disturbances on page 36. Transformer Step-up or step-down transformer See Connecting the Mains on (55 kVA) needed for sites that require page 35. 60 Hz, according to national authority electrical regulations. Pneumatic and Extraction Requirements Air compressor • Operating pressure: 7-8 bar (101.5-117.6 psi) See Air Compressor Requirements on page 39. • Minimum flow rate: 1200 liters/ min. (43 CFM) • Filtration: 5 microns • Reservoir size: 400 liters (106 gal.) Air dryer • Operating pressure: 7-8 bar (101.5-117.6 psi) • Minimum flow rate: 1200 liters/ min. (43 CFM) • Dew point: 2°C (35.6°F) See Air Dryer Requirements on page 39. Maximum tube/hose lengths • Vacuum pump to machine: 15 m (49 ft.) • Bridge outlet to UV extraction inlet: 10 m (33 ft.) • UV extraction outlet to site extraction system: 10 m (33 ft.) See Positioning Peripheral Components on page 25. Environmental Requirements Lighting According to local regulations. See Lighting on page 39. Sunlight must be filtered to block 99.97% of UV light. Artificial sources of light should not have spectral peaks below 400 nm. Recommended lighting is fluorescent lights with plastic covers. Metal halide lighting should be replaced with fluorescent lighting or filtered accordingly. Chapter 2 - Customer Responsibilities 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

Chapter 2 - Customer Responsibilities
9
Site protection (amperage)
50 Hz: Printing unit: 75A,
UV system: 90 A
60 Hz: Printing unit: 75A,
UV system: 80 A
See
Electrical Requirements
on
page 28.
Voltages
50 Hz: 3-phase 400 V
(-5% /+10%)
60 Hz: 3-phase 480 V, 400 V or
208 V
(-5% /+10%)
See
Electrical Requirements
on
page 28.
Voltage spikes
+5% or -10%
See
Power Line Disturbances
on
page 36.
Transformer
Step-up or step-down transformer
(55 kVA) needed for sites that require
60 Hz, according to national
authority electrical regulations.
See
Connecting the Mains
on
page 35.
Pneumatic and Extraction Requirements
Air compressor
Operating pressure: 7-8 bar
(101.5-117.6 psi)
Minimum flow rate: 1200 liters/
min. (43 CFM)
Filtration: 5 microns
Reservoir size: 400 liters (106 gal.)
See
Air Compressor Requirements
on page 39.
Air dryer
Operating pressure: 7-8 bar
(101.5-117.6 psi)
Minimum flow rate: 1200 liters/
min. (43 CFM)
Dew point: 2
°
C (35.6
°
F)
See
Air Dryer Requirements
on
page 39.
Maximum tube/hose lengths
Vacuum pump to machine: 15 m
(49 ft.)
Bridge outlet to UV extraction
inlet: 10 m (33 ft.)
UV extraction outlet to site
extraction system: 10 m (33 ft.)
See
Positioning Peripheral
Components
on page 25.
Environmental Requirements
Lighting
According to local regulations.
Sunlight must be filtered to block
99.97% of UV light. Artificial sources
of light should not have spectral
peaks below 400 nm.
Recommended lighting is fluorescent
lights with plastic covers. Metal halide
lighting should be replaced with
fluorescent lighting or filtered
accordingly.
See
Lighting
on page 39.
Table 2-1
Summary of Site Preparation Specifications