HP Scitex FB10000 Site Preparation Guide Rev. 2 - Page 34
Protecting Pipes and Cables, FB10000 Layout, Storage Area for, Consumables and Substrates
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Table 4-5 Maximum Recommended Length - Pipes & Hoses Connection Maximum Length Details UV extraction fan outlet to 15 m (49 ft.) customer site extraction system 250 mm (10") diameter, galvanized steel, terminated at least 5 m (16.4 ft.) above head height, up to three 90º bends. The pressure drop should be less than 1.5 mBar (0.02 psi) with a flow rate of 1500 m3/hr. (883 CFM). Note: The customer is responsible for completing this connection. • A suggested floor plan for operation and service access around the HP Scitex FB10000 Industrial Press system is shown in FB10000 Layout on page 78. It is essential to check that your intended location is suitable for this floor plan. If you have any doubts, consult your local Installation Manager. • In addition to the print production area, extra space will be required in a separate area for the storage of inks and substrates, as described in Storage Area for Consumables and Substrates on page 41. Protecting Pipes and Cables It is the customer's responsibility to protect the pipes and cables that connect the external components to the HP Scitex FB10000 Industrial Press with a secure, metal cover (height: 170 mm/6.7 in.). Alternatively, the customer may place the cables in a channel dug into the floor of the site. The channel must be covered properly to prevent a safety hazard. Figure 4-2 Covering the Inlet Pipes and Cables 26 HP Scitex FB10000 Site Preparation Guide, Rev. 2