HP d640 HP D640 High-Volume Printer - Installation Manual (Printer and Accesso - Page 125
Setting Up the Serial Interface, Comms.serial, Online
View all HP d640 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 125 highlights
Host Interface Procedure 3: Setting the Printer's Communication Interface Setting Up the Serial Interface Press the Down Arrow button to highlight serial and press the Right Arrow button to select the serial submenu. See Figure 3-8: Comms.serial Online Online baud = 19200 stopbits = 1BIT parity = none flow = XON/XOFF dtr = HI/LO levels = RS232 Figure 3-8 Comms.serial Submenu Select levels. See Figure 3-9. Comms.serial.levels = RS232 RS422 Online Online Select Figure 3-9 Comms.serial.levels Submenu Highlight the serial interface you are using and press Select. From the Comms.serial submenu (see Figure 3-10, on page 3-24), you can set the following serial interface options: • baud • stopbits • parity • flow • dtr Host Computer Interface Installation and Configuration 3-23