Page 242 highlights
11: Remote Power Managers Critical SNMP Traps If enabled, under critical conditions (UPS goes onto battery power, UPS battery is low, UPS forced shutdown in progress, UPS on line power, UPS battery needs to be replaced, RPM is unavailable, communications with RPM lost, communications with RPM established), a EMGEventRPMAction trap will be sent to the NMS configured in the SNMP settings. This requires that SNMP traps be enabled. Critical Emails If an email address is specified, under critical conditions (see Critical SNMP Traps above), an email notification will be sent to the email address. The Server and Sender configured in the SSH settings will be used to send the email. Low Battery For UPS devices only. Indicates the behavior to take when the UPS reaches a low battery state. Options are to Shutdown this UPS - shutdown only the UPS that has reached a low battery state; Shutdown all UPSes - shutdown all UPSes managed by the EMG; Allow battery failure - allow the battery to completely fail, which may result in the unsafe shutdown of the devices it provides power to; Shutdown both EMG UPSes - shutdown both UPSes that provide power to the EMG, including the UPS with that has reached a low battery state (some EMGs have dual power supplies). For more information, see RPM Shutdown Procedure. Shutdown Order For UPS devices only. If any of the UPSes managed by the EMG reaches a low battery state AND is configured for Shutdown all UPSes for its Low Battery setting, this indicates the order in which this UPS will be shutdown. All UPSes with a shutdown order of "1" will be shutdown first, followed by all UPSes with a shutdown order of "2", etc. Shutdown orders are in the range of 1 to 49, with 50 being reserved for UPSes that provide power to the EMG they will always be shutdown last (see Provides EMG Power below). Provides EMG Power For UPS devices only. Indicates if this UPS provides power to the EMG. 4. Click Apply to Save. RPMs - Manage Device The Manage Device page allows the administrator to modify the settings for a managed RPM. To modify a managed RPM: 1. Click the Devices tab and select the RPMs option. Figure 11-1 Devices > RPMs shows the page which displays. 2. Select an RPM and click the Manage Device link. Figure 11-8 RPMs - Manage Device shows the page which displays. EMG™ Edge Management Gateway User Guide 242