Panasonic AW-HE130 Operating Instructions - Page 75
Refresh interval, Unicast port1 Image, Unicast port2 Audio, Max bit rate per client, Image quality
![]() |
View all Panasonic AW-HE130 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Web screen configurations (continued) Max bit rate (per client) Specify the H.264 bit rate per client. When [Transmission priority] is set to [Best effort], specify the maximum and minimum but rate. Setting value: 64kbps/128kbps *1 /256kbps *1 /384kbps *1 /512kbps *1 / 768kbps *1 /1024kbps *1 /1536kbps *1 /2048kbps *1 /3072kbps *1 / 4096kbps *1 /6144kbps *1 /8192kbps *1 /10240kbps *1 / 12288kbps *1 /14336kbps *1 /16384kbps *1 /20480kbps *1 / 24576kbps *1 Factory settings: H.264(1): 4096kbps H.264(2): 1536kbps H.264(3): 1024kbps H.264(4): 512kbps The range of H.264 bit rates that can be specified varies depending on the resolution. • 160 × 90: 64kbps to 2048kbps • 320 × 180, 640 × 360: 64kbps to 4096kbps • 1280 × 720: 256kbps to 8192kbps • 1920 × 1080: 512kbps to 14336kbps • 1920 × 1080 (60fps), 1280 × 720 (60fps): 1024kbps to 24576kbps *1 The H.264 bit rate is limited by the [Bandwidth control (bitrate)] (→ page @@) setting under the [Network] tab of the Network screen. The actual bit rate may be lower than the specified value. Image quality Select the image quality for H.264 images. Setting value: Low(Motion priority) / Normal / Fine(Image quality priority) Factory settings: Normal • This setting is only enabled when [Transmission priority] (→ page @@) is set to [Constant bit rate] or [Best effort]. Refresh interval Select the refresh interval for H.264 images (I-frame interval: 0.2 to 5 seconds). If errors occur frequently in the network environment, decreasing the refresh interval will reduce image distortions. However, the frame rate may decrease. Setting value: For 60Hz: 0.2s / 0.25s / 0.33s / 0.5s / 1s / 2s / 3s / 4s / 5s For 50Hz: 0.2s / 0.5s / 1s / 2s / 3s / 4s / 5s Factory settings: 1s Transmission type Select the transmission format for H.264 images. Setting value: Unicast port (AUTO) Up to 24 users can access a single camera at the same time. [Unicast port1 (Image)] and [Unicast port2 (Audio)] will be configured automatically when images and audio are sent from the camera. We recommend selecting the [Unicast port (MANUAL)] setting when the port number transmitting the H.264 images does not need to be fixed (e.g., during use within a network). Unicast port (MANUAL) Up to 24 users can access a single camera at the same time. [Unicast port1 (Image)] and [Unicast port2 (Audio)] must be configured manually when images and audio are sent from the camera. When transmitting H.264 images via the Internet, configure a fixed transmission port for the broadband router (hereafter referred to as "router") (→ page @@). For details, refer to the operating instructions for the router. Multicast port An unlimited number of users can access a single camera at the same time. When transmitting H.264 images via multicast, enter the [Multicast address], [Multicast port], and [Multicast TTL/HOPLimit]. Factory settings: Unicast port (AUTO) • For details on the maximum number for simultaneous access, see page @@. Unicast port1 (Image) *1 Enter the unicast port number (used when sending images from the unit). Usable port number range: 1024 to 50000 • Only even numbers can be specified. • The port number cannot be set to 10670. Factory settings: H.264(1): 32004 H.264(2): 32014 H.264(3): 32024 H.264(4): 32034 *1 The unicast port number must be configured when [Transmission type] is set to [Unicast port (MANUAL)]. Unicast port2 (Audio)*1 Usable port number range: 1024 to 50000 • Only even numbers can be specified. • The port number cannot be set to 10670. Factory settings: H.264(1): 32004 H.264(2): 32014 H.264(3): 32024 H.264(4): 32034 *1 The unicast port number must be configured when [Transmission type] is set to [Unicast port (MANUAL)]. 75
![](/manual_guide/products/panasonic-awhe130-operating-instructions-4f3ed63/75.png)