Dell PowerEdge R910 Hardware Owner's Manual - Page 34
E1A14 SAS cable A, E1814 Internal SD
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Code Text Causes Corrective Actions E1812 Hard drive ## The specified hard drive has Information only. removed. been removed from the Check drive. system. E1813 Internal Dual The internal dual SD SD Module module card has failed. Card # failed. Check SD card. Reseat the internal dual SD module card. If the problem persists, see "Getting Help" on page 203. E1814 Internal SD The internal dual SD Module Card # module card is write- writeprotected. protected and cannot be used. Check SD card. Change the write-protect switch setting on SD card. E1815 Internal Dual The internal dual SD SD Module module bootable media is redundancy no longer redundant. lost. Check SD cards. Initiate a rebuild on the next POST execution. Reseat the internal dual SD module card. See "Removing an Internal SD Card" on page 142 and "Installing an Internal SD Card" on page 142. If the problem persists, see "Getting Help" on page 203. E1A14 SAS cable A failure. Check connection. SAS cable A is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 203. 34 About Your System