Dell PowerEdge R910 Hardware Owner's Manual - Page 55
See Getting Help on, Troubleshooting a Hard
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Message Causes Corrective Actions SATA port x device autosensing error The drive connected to the Replace the faulty drive. specified SATA port is faulty. SATA port x device configuration error. SATA port x device error Sector not found Faulty hard drive, USB Seek error device, or USB medium. Seek operation failed Replace the USB medium or device. Ensure that the USB or SAS backplane cables are properly connected. See "Troubleshooting a USB Device" on page 174 or "Troubleshooting a Hard Drive" on page 186 for the appropriate drive(s) installed in your system. Shutdown failure General system error. See "Getting Help" on page 203. The amount of Memory has been added or system memory has removed or a memory changed. module may be faulty. If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 181. Time-of-day clock stopped. Faulty battery or faulty chip. See "Troubleshooting the System Battery" on page 178. About Your System 55