address, value, See Troubleshooting System
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Message Causes Corrective Actions DellMemBIST timeout: Memory riser DIMM Memory riser lockstep pair DIMM disabled. The memory modules are not Replace or reseat the properly seated. memory module(s). See The memory module "Removing Memory connector may be exposed to Modules" on page 105 and dust. "Installing Memory Modules" on page 102. Faulty memory module. Ensure that the memory module connectors are clean. Please replace the DIMM(s) or remove the lockstep pair. DellMemBIST error: Memory riser DIMM Memory riser lockstep pair DIMM disabled. Please replace the DIMM or remove the lockstep pair. Manufacturing mode detected. System is in manufacturing Reboot to take the system mode. out of manufacturing mode. Memory address line failure at address, read value expecting value. Faulty or improperly installed See "Troubleshooting System memory modules. Memory" on page 181. Memory double word logic failure at address, read value expecting value. Faulty or improperly installed See "Troubleshooting System memory modules. Memory" on page 181. About Your System 51