Dell PowerEdge R910 Hardware Owner's Manual - Page 51

address, value, See Troubleshooting System

Page 51 highlights

Message Causes Corrective Actions DellMemBIST timeout: Memory riser DIMM Memory riser lockstep pair DIMM disabled. The memory modules are not Replace or reseat the properly seated. memory module(s). See The memory module "Removing Memory connector may be exposed to Modules" on page 105 and dust. "Installing Memory Modules" on page 102. Faulty memory module. Ensure that the memory module connectors are clean. Please replace the DIMM(s) or remove the lockstep pair. DellMemBIST error: Memory riser DIMM Memory riser lockstep pair DIMM disabled. Please replace the DIMM or remove the lockstep pair. Manufacturing mode detected. System is in manufacturing Reboot to take the system mode. out of manufacturing mode. Memory address line failure at address, read value expecting value. Faulty or improperly installed See "Troubleshooting System memory modules. Memory" on page 181. Memory double word logic failure at address, read value expecting value. Faulty or improperly installed See "Troubleshooting System memory modules. Memory" on page 181. About Your System 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

About Your System
51
DellMemBIST
timeout: Memory
riser <x> DIMM
<y>
Memory riser <x>
lockstep pair
DIMM <x & y>
disabled.
Please replace
the DIMM(s) or
remove the
lockstep pair.
The memory modules are not
properly seated.
The memory module
connector may be exposed to
dust.
Faulty memory module.
Replace or reseat the
memory module(s). See
"Removing Memory
Modules" on page 105 and
"Installing Memory Modules"
on page 102.
Ensure that the memory
module connectors are clean.
DellMemBIST
error: Memory
riser <x> DIMM
<y>
Memory riser <x>
lockstep pair
DIMM <x & y>
disabled.
Please replace
the DIMM or
remove the
lockstep pair.
Manufacturing
mode detected.
System is in manufacturing
mode.
Reboot to take the system
out of manufacturing mode.
Memory address
line failure at
address
, read
value
expecting
value.
Faulty or improperly installed
memory modules.
See "Troubleshooting System
Memory" on page 181.
Memory double
word logic
failure at
address
, read
value
expecting
value.
Faulty or improperly installed
memory modules.
See "Troubleshooting System
Memory" on page 181.
Message
Causes
Corrective Actions