W1100 Cpu Vcore, I1912 Sel Full. - chassis
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Code Text Causes Corrective Actions E2112 Memory spared The system BIOS spared the Remove AC power to the on Card x memory because it has system for 10 seconds and DIMM ##. determined the memory has restart the system. Power cycle too many errors. AC. If the problem persists, see "Troubleshooting System Memory" on page 181. E2113 Mem mirror OFF on DIMM ## & ##. Power cycle AC. The system BIOS disabled memory mirroring because it has determined one half of the mirror has had too many errors. "## & ##" represents the memory module pair implicated by the BIOS. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Troubleshooting System Memory" on page 181. I1910 Intrusion detected. System cover has been removed. Check chassis cover. Information only. I1911 LCD Log Full. Check SEL to review all Errors. LCD overflow message. A maximum of ten error messages can display sequentially on the LCD. The eleventh message instructs the user to check the SEL for details on the events. Check the SEL for details on the events. Remove AC power to the system for 10 seconds or clear the SEL. I1912 SEL full. Review & clear log. The SEL is full of events and is unable to log any more. Check the SEL for more information and then clear the SEL. W1100 CPU VCORE Regulator temp exceeding range. Check fans. The regulator temperature has reached a point outside of the allowed range. See "Troubleshooting System Cooling Problems" on page 180. If the problem persists, see "Getting Help" on page 203. About Your System 39