Dell PowerEdge R910 Hardware Owner's Manual - Page 35
E1A15 SAS cable B, E2013 BIOS unable - memory riser
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Code Text Causes Corrective Actions E1A15 SAS cable B failure. Check connection. SAS cable B is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 203 E1A1D Control panel USB cable to the control USB cable not panel is missing or bad. detected. Check cable. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 203. E2010 Memory not detected. Inspect DIMMs. No memory was detected in Install memory or reseat the system. the memory risers and memory modules. See "Installing a Memory Riser" on page 101, "Installing Memory Modules" on page 102 or "Troubleshooting System Memory" on page 181. E2011 Memory configuratio n failure. Check DIMMs. Memory detected, but is not See "Troubleshooting configurable. Error detected System Memory" on during memory page 181. configuration. E2012 Memory configured Memory configured, but is unusable. but unusable. Check DIMMs. See "Troubleshooting System Memory" on page 181. E2013 BIOS unable The system BIOS failed to to shadow copy its flash image into memory. Check memory. DIMMs. See "Troubleshooting System Memory" on page 181. About Your System 35