Printer Specifications Electrical Voltage 120 VAC, f 10% (USA) 220 VAC, f 10% (Europe) Non-switchable Power consumption 120 Watts maximum Frequency 49.5 to 60.5 Hz Insulation resistance 10 MQ between AC power line and chassis Dielectric strength 120 V model can withstand 1.25 kV rms applied between AC line and chassis for 1 minute, or 1.5 kV rms for 1 second Environment Temperature Operation: 41" F to 95" F (5" C to 35" C) Storage: - 22" F to 150" F (- 30" C to 65" C) Humidity Operation: 10% to 80% without condensation Storage: 5% to 85% without condensation Shock Operation: Up to 1 G within 1ms Storage: Up to 2 G within 1ms Vibration Operation: Up to 0.25 G at up to 55 Hz Storage: Up to 0.5 G at up to 55 Hz 8-5
Printer Specifications
Electrical
Voltage
120 VAC,
f
10% (USA)
220 VAC,
f
10% (Europe)
Non-switchable
Power consumption
120 Watts maximum
Frequency
49.5 to 60.5 Hz
Insulation resistance
10
MQ
between AC power line and chassis
Dielectric strength
120 V model can withstand 1.25
kV
rms applied between AC
line and chassis for 1 minute, or 1.5
kV
rms for 1 second
Environment
Temperature
Operation:
41”
F to
95”
F (5” C to
35”
C)
Storage:
-
22”
F to
150”
F
(-
30”
C to
65”
C)
Humidity
Operation: 10% to 80% without condensation
Storage: 5% to 85% without condensation
Shock
Operation: Up to 1 G within 1ms
Storage: Up to 2 G within 1ms
Vibration
Operation: Up to 0.25 G at up to 55 Hz
Storage: Up to 0.5 G at up to 55 Hz