Epson LQ 1050 User Manual - Page 163
Pulled up to +5V through 3.3K, Same as for Pins 19-30.
View all Epson LQ 1050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 163 highlights
Interface Specifications Pulled up to +5 volts through 32 - ERROR 33 - GND 34 - NC 35 - - 36 - SLCT IN OUT IN LOW, the printer controller is reset to its power-up state and the print buffer is cleared. This level is usually HIGH; its pulse width must be more than 50 microseconds at the receiving terminal. This level becomes LOW when the printer is in: 1) Paper-end state. 2) Off-line 3) Error state Same as for Pins 19-30. Unused. Pulled up to +5V through 3.3K ohm resistance The DC1/DC3 code is valid only when this signal is "HIGH" (Internal fixing can be carried out with Jumper J9. The level of this signal is factory-set to "LOW".) 8-7
Interface Specifications
Pulled up to
+5
volts through
LOW, the printer controller is reset
to its power-up state and the print
buffer is cleared. This level is
usually HIGH; its pulse width must
be more than 50 microseconds at
the receiving terminal.
32
-
ERROR
OUT
This level becomes LOW
when the printer is in:
1) Paper-end state.
2) Off-line
3) Error state
33
-
GND
34
-
NC
35
-
-
-
Same as for Pins 19-30.
-
Unused.
-
Pulled up to +5V through 3.3K
ohm resistance
36
-
SLCT IN
IN
The DC1/DC3 code is valid
only when this signal is “HIGH”
(Internal fixing can be carried out
with Jumper J9. The level of this
signal is factory-set to “LOW”.)
8-7