Serial interface, Space 0 + 3V to + 27V
View all Epson LQ 1050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 165 highlights
Interface Specifications Printing enabled/disabled signals and control conditions The table below shows the relationship between printing being enabled or disabled, and the on-line/off-line condition, the printer select signal (SLCT IN), and the receipt of data on/off control character, DC1/DC3. On-line (Indicator on) ON-LINE SLCT IN Low (J9/ interface) DCllDC3 ERROR (Data on/off control) DClIDC3 High (no effect) ON-LINE High DC1 Recv'd High ON-LINE High DC3 Recv'd High OFF-LINE High/Low DCl/DCB Low (no effect) (no effect) BUSY ACKNLG Printing (Disabled/ enabled) High/Low High/low High/Low High Pulsed ea. char. Pulsed ea. char. Pulsed ea. char. Not generated Enabled (normal cond.) Enabled *Disabled Disabled *Even though printing is disabled, data characters are received and acknowledged, since the printer is looking for another DC1 character, which would allow it to resume printing. Serial interface The LQ built-in serial interface is an RS-232C asynchronous interface with the following characteristics: Data format 1 start bit Data word length: 8 bits Odd, even or no parity 1 stop bit Signal level Mark (1) - 3V to - 27V Space (0) + 3V to + 27V Band rate 300, 1200, 4800, 9600 BPS 8-9