HP StorageWorks MSA 2/8 HP StorageWorks Fabric Watch V3.1.x/4.1.x User Guide ( - Page 134
Messages, Port Invalid CRCs
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
Responding to Fabric Watch Messages Messages Message Description Troubleshooting FW-CHANGED, 4 portCRCs (Port Invalid CRCs ) value has changed. current value : Error(s)/minute. (info) Explains that the number of invalid CRC errors per minute has changed. Provides the new value. This is an informational message. Respond to this message as is appropriate to the particular policy of the end-user installation. Message Description Troubleshooting FW-ABOVE, 3, portCRCs (Port Invalid CRCs ) is above high boundary. current value : Error(s)/minute. (faulty) Explains that the number of invalid CRC errors per minute has risen above the high boundary. Provides the new value. This error generally indicates an aging fabric. Check your SFPs, cables, and connections for faulty hardware. Verify that all optical hardware is clean. Message Description Troubleshooting FW-BELOW, 3, portCRCs (Port Invalid CRCs ) is below low boundary. current value : Error(s)/minute. (normal) Explains that the number of invalid CRC errors per minute has fallen below the low boundary. Provides the new value. This message is informational. Respond to this message as is appropriate to the particular policy of the end-user installation. Message Description Troubleshooting WARNING EXCEEDED, 3, portCRCs (Port Invalid CRCs ) is exceeded boundary. current value : Error(s)/minute. (info) Explains that the number of invalid CRC errors per minute has risen above or fallen below the acceptable range. Provides the new value. This message is informational. Respond to this message as is appropriate to the particular policy of the end-user installation. Message FW-INBETWEEN, 3 portCRCs (Port Invalid CRCs ) is between high & low boundaries. current value : Error(s)/minute. (info) 134 Fabric Watch Version 3.1.x/4.1.x User Guide