HP StorageWorks MSA 2/8 HP StorageWorks Fabric Watch V3.1.x/4.1.x User Guide ( - Page 198
Core Switch 2/64 Threshold Defaults, Table 21: Environment-Class Threshold Defaults
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 198 highlights
Default Threshold Values Core Switch 2/64 Threshold Defaults Table 21 provides default settings for areas in the Environment class. Table 21: Environment-Class Threshold Defaults Area Temperature Fan Power Supply Description Monitors switch temperature in Celsius Monitors switch fan speed in RPMs Monitors power supply condition Default Threshold Settings Unit: C Time Base: Low: 0 High: 75 Buffer: 10 Unit: RPM Time Base: Low: 2000 High: 3400 Buffer: 3 Unit: 1OK/0FAULTY Time Base: Low: 1 High: 0 Buffer: 0 Default Alarm Settings Changed: 0 Exceeded: 0 Below: 3 Above: 3 In-between: 3 Changed: 0 Exceeded: 0 Above: 3 Below: 3 In-between: 1 Changed: 0 Exceeded: 0 Below: 3 Above: 3 In-between: 0 Threshold State Informative Faulty Faulty Faulty Normal Informative Informative Normal Faulty Informative Informative Informative Faulty Normal Informative 198 Fabric Watch Version 3.1.x/4.1.x User Guide