HP StorageWorks MSA 2/8 HP StorageWorks Fabric Watch V3.1.x/4.1.x User Guide ( - Page 213
SAN Switch 2/32 Threshold Defaults, Table 32: Environment-Class Threshold Defaults
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 213 highlights
Default Threshold Values SAN Switch 2/32 Threshold Defaults Table 32 provides default settings for areas in the Environment class. Table 32: Environment-Class Threshold Defaults Area Temperature Fan Power Supply Description Monitors switch temperature in Celsius Monitors switch fan speed in RPMs Monitors power supply condition Default Threshold Settings Unit: C Time Base: Low: 0 High: 67 Buffer: 10 Unit: RPM Time Base: Low: 2600 High: 10,000 Buffer: 3 Unit: 1OK/0FAULTY Time Base: Low: 1 High: 0 Buffer: 0 Default Alarm Settings Changed: 0 Exceeded: 0 Below: 3 Above: 3 In-between: 3 Changed: 0 Exceeded: 0 Above: 3 Below: 3 In-between: 1 Changed: 0 Exceeded: 0 Below: 3 Above: 3 In-between: 0 Threshold State Informative Faulty Faulty Faulty Normal Informative Informative Normal Faulty Informative Informative Informative Faulty Normal Informative Fabric Watch Version 3.1.x/4.1.x User Guide 213