Icom VE-PG3 Instruction Manual - Page 116
When [IP Communication Mode] is set to [Unicast]
View all Icom VE-PG3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
5 BRIDGE MODE SETTING SCREEN 7. [Bridge Connection] Menu M Bridge Connection Point (continued) [Bridge Connection]-[Bridge Connection] rConnection Port Number Enter the destination's VE-PG3 port number. (Enter the same port number as in the [My Station Port Number](t) item.) • S etting range: Even numbers between 2 and 65534 (Some numbers may not be acceptable.) • T he set port number (RTP) and the port number +1 (RTCP) are used for the communication. • When using in the Unicast mode, do not set the port number which has already been used by another connection setting. • The default number differs, depending on the setting as shown below. (Default: 2 1504(Digital Transceiver 1(D-TRX1)), 21506(Digital Transceiver 2(D-TRX2)), 21508(Digital Transceiver 3(D-TRX3)), 21510(Digital Transceiver 4(D-TRX4)), 21520(Emergency), When [IP Communication Mode] is set to [Unicast]: 21500(Transceiver 1(TRX1)), 21502(Transceiver 2(TRX2)), 21512(External Input1 (EXT1), External I/O 1(EXT1)), 21514(External Output1 (EXT1)), 21516(External Input2 (EXT2), External I/O 2(EXT2)), 21518(External Output2 (EXT2)), When [IP Communication Mode] is set to [Multicast]: 22510(Transceiver 1(TRX1), Transceiver 2(TRX2), External Input1 (EXT1), External Output1 (EXT1), External I/O 1(EXT1), External Input2 (EXT2), External Output2 (EXT2), External I/O 2(EXT2)) 5-53