Icom VE-PG3 Instruction Manual - Page 262
When the input port is pulled up, Short circuit LOW, Open circuit HIGH, Control Input Pull-up Setting
View all Icom VE-PG3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 262 highlights
6 CONVERTER MODE SETTING SCREEN 9. [Port Settings] Menu (continued) M EXT Control Terminal (continued) [Port Settings]-[EXT Input 1 (EXT1)/EXT Input 2 (EXT2)] e Event OFF Time r Control Input Detection � t Control Input Pull-up Setting Select the delay time until the port B3/B4 terminal (General control input)) is deactivated. (Default: 1) Range: [0.1], [0.3], [0.5], [1], [1.5], [2], [3](second) Select the port input state of B3/B4 terminal (General control input). (Default: Short circuit (LOW)) When the input port is pulled up: • Short circuit (LOW) : A ctive when the B3/B4 terminal (General control input) is connected to the GND (LOW). • Open circuit (HIGH) : A ctive when the B3/B4 terminal (General control input) is open (HIGH). When the input port is NOT pulled up: • Short circuit (LOW) : Active when no voltage is applied to the B3/B4 terminal (General control input). • Open circuit (HIGH) : A ctive when a voltage is applied to the B3/B4 ter- minal (General control input). Select "Enable" to internally pull up the B3/B4 terminal (General control input). (Default: Enable) 6-83