Page 256 highlights
6 CONVERTER MODE SETTING SCREEN 9. [Port Settings] Menu (continued) [Port Settings]-[EXT Input 1 (EXT1)/EXT Input 2 (EXT2)] MEXT Voice Terminal Set the details of the input audio from the [EXT1]/[EXT2] port. q Input Connection Port �� Select the port to input the audio signal. (Default: IP Network) • E XT Output: S ends the audio signal to the . [EXT1]/[EXT2] port. • IP Network: Sends the audio signal to the IP network. • The audio signal is sent to the port set in [Bridge Connection Point] on the [Bridge Connection] screen. • Emergency: Sends the audio signal to the device which is specified as the emergency call destination. • Emergency communication has priority over normal commu- nication. • Emergency communication has priority over normal commu- nication. • The VE-PG3 enters the Emergency mode when the condi- tion specified in [Enable Timing] on the [External Input1 (EXT1)] screen is satisfied. • In the Emergency mode, all ongoing communication routes, other than which is for the Emergency Notice, are discon- nected. • To transmit the call as the Emergency Notice, set the port type to "Emergency Notice" on the [Bridge Connection Point] screen, and set the Emergency Notice device to "Enable" on the [Emergency Notice] screen. 6-77