Page 254 highlights
6 CONVERTER MODE SETTING SCREEN 9. [Port Settings] Menu (continued) [Port Settings]-[Digital Transceiver1 (D-TRX1)-Digital Transceiver4 (D-TRX4)] MV/RoIP Control (Digital Transceiver) Set the details for receiving a call on the radio connected to [D-TRX1]/[D-TRX2] port. q Send Connect Success Tone to Telephone Select "Tone 1" to "Tone 3" to notify that the connection to the calling IP phone is succeeded. (Default: Tone 1) w Send and Receive Change Notice to the Telephone: Select "Tone 1" to "Tone 3" to notify when the TX and RX are changed. (Default: Not used) e Notice Tone Volume ��� Select the tone level for above items. Range: "+6" to "-12" (dB) (Default: 0) 6-75
6
CONVERTER MODE SETTING SCREEN
6-75
9. [Port Settings] Menu (continued)
M
V/RoIP Control (Digital Transceiver)
Set the details for receiving a call on the radio connected to [D-TRX1]/[D-TRX2] port.
q
Send Connect Success Tone to Telephone
Select “Tone 1” to “Tone 3” to notify that the connection to the calling IP
phone is succeeded.
(Default: Tone 1)
w
Send and Receive Change Notice to the Telephone:
Select “Tone 1” to “Tone 3” to notify when the TX and RX are changed.
(Default: Not used)
e
Notice Tone Volume ………
Select the tone level for above items.
(Default: 0)
Range: “+6” to “–12” (dB)
[Port Settings]–[Digital Transceiver1 (D-TRX1)–Digital Transceiver4 (D-TRX4)]