Icom VE-PG3 Instruction Manual - Page 50
Operation, When an emergency situation is detected
View all Icom VE-PG3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
3 CONVERTER MODE APPLICATION 5. Emergency Notice (continued) 3. Operation When an emergency situation is detected, an emergency announcement to the external audio device and radio is made. Area A Announcement output Emergency device Extension No. 302 Ext. AMP Audio device (For BGM) Audio input General control input Audio output Audio input (A3/A4 terminal) (B3/B4 terminal) (A1/A2 terminal) (A3/A4 terminal) Area B HUB Extension No. 301 [EXT2] [TRX1] [EXT1] IP Phone No. 32 Radio A1 Radio A VE-PG3 (192.168.0.2) IP Network [LAN] Extension No. 401 VE-PG3 (192.168.0.3) IP telephone (KX-UT Series) An example of operation with an emergency notice device • All radios in the area must have same setting. [When an emergency situation occurs.] q Area A When an emergency situation is detected, the external switch turns ON. w Area A The ongoing regular call and BGM is cancelled, and then the emergency announcement is made. • Radio A automatically transmit the announcement. e Area A When the external switch is turned OFF, the emergency announcement is cancelled. • The BGM resumes. NOTE: • Full duplex communication is impossible. Communicate with each other by taking turns speaking. • Pause briefly before you speak, to confirm your party has finished speaking. • The communication route will be disconnected when the IP telephone's handset is put on the hook, or the VE-PG3 receives no audio for the preset time (default: 15 seconds). 3-26