Control Circuit EXT Output, Select Enable when supply the 8 V to the EXT Output terminal B2/B4
View all Icom VE-PG3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 265 highlights
6 CONVERTER MODE SETTING SCREEN 9. [Port Settings] Menu (continued) [Port Settings]-[EXT Output 1 (EXT1)/ EXT Output 2 (EXT2)] MControl Circuit (EXT Output) Configure the details for the control circuit connected to the [EXT1]/[EXT2] port. Control Circuit Switching: Control output Circuit Control Circuit Switching: Relay Circuit q Control Circuit Switching � w Control Output Logic �� Select the control circuit type. (Default: Control Output Circuit) Select the activate state.(Default: Low) e Control Output Logic �� Select the port state. Relay output terminal (B1/B2 terminal) is short circuit or open circuit. (Default: Short) When the audio signal is output, the control signal is also output. r 8V Power Source Select "Enable" when supply the 8 V to the EXT Output terminal (B2/B4 terminal), when a microphone is connected. (Default: Disable) Current limit: Less than 30 mA 6-86