Error, Description, Action, > = CRC Failure or ECC Failure
View all Lexmark E238 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
4511-xxx Service error codes (9xx) (continued) Error Description 952 NV failure:n 954 NVRAM CRC failure 955 Code CRC 956 Controller card 957 ASIC failure 958 NAND failure 959 SRAM failure 960 RAM soldered on the card is bad 961 RAM in slot 1 is bad Action Recoverable error. Reset (POR) the printer. Where n=offset where error occurred. Indicates the NVRAM experienced a CRC failure. Replace the controller card. Replace the controller card. Where = CRC Failure or ECC Failure on the controller card. Perform a power on reset (POR). If this does not fix the problem, replace the controller card. Perform a power on reset (POR). If this does not fix the problem, replace the controller card. Before proceeding, perform a power on reset (POR) to see if the ECC (error correction code) can reflash NAND. If this does not fix the problem, replace the controller card. Perform a power on reset (POR). If this does not fix the problem, replace the controller card. Indicates a DRAM Memory Error on the controller card. Replace the controller card. If another SDRAM memory DIMM is available, turn the power off, and switch the DIMM. If the memory card now works correctly, replace the failing DIMM. If this does not fix the problem, replace the controller card. If another DIMM is not available, replace the memory option first and then the controller card if necessary. Diagnostics-E340 and E342n 2-67