Main motor service check
View all Lexmark T430 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
4048-1xx Main motor service check FRU Main motor Main motor cable Controller card assembly Action With the printer on, verify +24 V dc on pin #7 at J10 on the controller card assembly. • If the voltage is correct, check the main motor cable for continuity. - If continuity exists on each wire, replace the main motor. - If continuity does not exist on one or more of the wires, replace the motor cable. • If the voltage is not correct, verify +24 V dc on pins #1 and #2 on J17. - If voltage is correct, replace the controller card. - If the voltage is not correct, check the LVPS. Note: Always check printhead alignment after replacing the controller card assembly. See "Printhead assembly adjustment" on page 4-2 for hardware alignment of the printhead. 2-42 Service Manual