Panasonic P2 HD Camcorder Operating Instructions - Page 150

Caution, REMOTE

Page 150 highlights

REMOTE 1 CAM DATA (H) 2 CAM DATA (C) 3 CAM CONT (H) 4 CAM CONT (C) 5 RC-ON 6 RC VIDEO OUT 7 RC VIDEO GND 8 NC 9 UNREG 12V 10 GND Data from the camera to the remote control (H) Data from the camera to the remote control (C) Control signals from the remote control to the camera (H) Control signals from the remote control to the camera (C) Identification signals of the remote control Low: ON Video signals output to the remote control GND of the video signals to the remote control Not used DC 12 V power supply (AJ-RC10G: Max. 0.75 A) GND Panasonic part number K1AY110JA001 Maker part number HR10A-10R-10SC(71) (Hirose Denki) Connector at the cable side Maker part number HR10A-10P-10P(73) (Hirose Denki) 8 1 7 10 9 2 6 5 3 4 VF 1 UNREG-12V 2 UNREG-12V 3 A9.0V 4 VF-PB-GND 5 VF-PR-GND 6 VF-Y 7 VF-Y-GND 8 VF-CLK 9 VF-WR 10 VF-DATA 11 UNREG-GND 12 ZEBRA-SW 13 PEAKING 14 SPARE 15 VF-PR 16 VF-PB 17 MARKER-SW 18 FRONT-VR 19 VR-GND 20 UNREG-GND DC 12 V power supply (AJ-HVF21KG: About 0.35 A) DC 12 V power supply DC 9 V power supply (not used) GND for the viewfinder PB signals GND for the viewfinder PR signals Viewfinder Y signals output GND for the viewfinder Y signals Serial data clock pulse signals Pulse signals for reading serial-parallel conversion data Serial data signals for serial-parallel conversion GND ON/OFF of the zebra signals Control of the peaking (not used) Standby (not used) Viewfinder PR signal output Viewfinder PB signal output ON/OFF of the marker (not used) FRONT AUDIO LEVEL adjustment (not used) GND for the FRONT AUDIO LEVEL (not used) GND ‹Caution Total amount of current from the respective connectors for DC OUT, REMOTE, VF, and LENS should not exceed 2.5 A. Panasonic part number K1AB120H0001 Maker part number HR12-14RA-20SC (Hirose Denki) 1 2 34 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 150 Maintenance and Inspections: Maintenance

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208

150
Maintenance and Inspections: Maintenance
REMOTE
1
CAM DATA (H)
Data from the camera to the remote control (H)
2
CAM DATA (C)
Data from the camera to the remote control (C)
3
CAM CONT (H)
Control signals from the remote control to the camera (H)
4
CAM CONT (C)
Control signals from the remote control to the camera (C)
5
RC-ON
Identification signals of the remote control
Low: ON
6
RC VIDEO OUT
Video signals output to the remote control
7
RC VIDEO GND
GND of the video signals to the remote control
8
NC
Not used
9
UNREG 12V
DC 12 V power supply (AJ-RC10G: Max. 0.75 A)
10
GND
GND
VF
1
UNREG-12V
DC 12 V power supply (AJ-HVF21KG: About 0.35 A)
2
UNREG-12V
DC 12 V power supply
3
A9.0V
DC 9 V power supply (not used)
4
VF-PB-GND
GND for the viewfinder P
B
signals
5
VF-PR-GND
GND for the viewfinder P
R
signals
6
VF-Y
Viewfinder Y signals output
7
VF-Y-GND
GND for the viewfinder Y signals
8
VF-CLK
Serial data clock pulse signals
9
VF-WR
Pulse signals for reading serial-parallel conversion data
10
VF-DATA
Serial data signals for serial-parallel conversion
11
UNREG-GND
GND
12
ZEBRA-SW
ON/OFF of the zebra signals
13
PEAKING
Control of the peaking (not used)
14
SPARE
Standby (not used)
15
VF-PR
Viewfinder P
R
signal output
16
VF-PB
Viewfinder P
B
signal output
17
MARKER-SW
ON/OFF of the marker (not used)
18
FRONT-VR
FRONT AUDIO LEVEL adjustment (not used)
19
VR-GND
GND for the FRONT AUDIO LEVEL (not used)
20
UNREG-GND
GND
±
Caution
Total amount of current from the respective connectors for DC OUT, REMOTE,
VF, and LENS should not exceed 2.5 A.
1
2
4
5
6
7
8
9
10
3
Panasonic part number
K1AY110JA001
Maker part number
HR10A-10R-10SC(71)
(Hirose Denki)
Connector at the cable side
Maker part number
HR10A-10P-10P(73)
(Hirose Denki)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1
8
19
20
Panasonic part number
K1AB120H0001
Maker part number
HR12-14RA-20SC
(Hirose Denki)