Panasonic P2 HD Camcorder Operating Instructions - Page 90

Handling data

Page 90 highlights

Handling data Set data file configuration The unit employs 6 sets for the file data area. FACTORY data: The area for storing factory settings. Data cannot be revised with menu operations. USER data: The area for storing the data set by menu operations The FACTORY data is stored as the factory setting. CURRENT data: The area for storing the operating status of the unit The set value in this area is revised by menu operations. SCENE file: Four sets of scene files are provided. LENS file: Eight sets of lens files are provided. CAC file: 32 chromatic aberration compensation data area sets are provided. > For menu items that can be read from or stored in the respective areas, refer to [Menu] (page 158) ‹Notes z For information about how to navigate through the menu for this section, see [Setting Menu Options] (page 160). z Access the respective data settings files after switching the PC MODE to "OFF". If the respective data settings files are accessed when the unit is in USB DEVICE mode, an error may occur. The menu item PC MODE is found in the screen on the SYSTEM SETTING page. It is possible to write eight setup files on the SD memory card. SD memory card SET UP data No. of files: 8 CAC ADJ CAC FILE DELETE Menu operations To revise the set value SD CARD READ/WRITE SD CARD READ/WRITE READ WRITE CAC FILE CARD READ DELETE CAC FILE CARD READ READ CAC file No. of files: 32 SD memory card CAC CONTROL SCENE WRITE SCENE file WRITE USER READ USER DATA DATA READ FACTORY DATA CURRENT data (Operating status of the unit) No. of files: 1 USER data No. of files: 1 FACTORY data (Revision disable) No. of files: 1 SCENE READ No. of files: 4 LENS FILE READ LENS FILE WRITE LENS file No. of files: 8 LENS FILE CARD R/W LENS FILE CARD R/W READ WRITE : Files built in the unit : Menu operations SD memory card Lens file No. of files: 8a8 It is possible to write eight titles for eight lens files on the SD memory card. 90 Adjustments and Settings for Recording : Handling data

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208

90
Adjustments and Settings for Recording
:
Handling data
The unit employs 6 sets for the file data area.
FACTORY data:
The area for storing factory settings.
Data cannot be revised with menu operations.
USER data:
The area for storing the data set by menu operations
The FACTORY data is stored as the factory setting.
CURRENT data:
The area for storing the operating status of the unit
The set value in this area is revised by menu operations.
SCENE file:
Four sets of scene files are provided.
LENS file:
Eight sets of lens files are provided.
CAC file:
32 chromatic aberration compensation data area sets
are provided.
>
For menu items that can be read from or stored in the
respective areas, refer to [Menu] (page 158)
±
Notes
z
For information about how to navigate through the menu for
this section, see
[Setting Menu Options] (page 160).
z
Access the respective data settings files after switching the
PC MODE to
“OFF”. If the respective data settings files are
accessed when the unit is in USB DEVICE mode, an error
may occur. The menu item PC MODE is found in the
<SYSTEM MODE> screen on the SYSTEM SETTING page.
Handling data
Set data file configuration
LENS FILE
READ
LENS FILE
WRITE
WRITE USER
DATA
READ USER
DATA
LENS FILE CARD R/W
WRITE
LENS FILE CARD R/W
READ
READ FACTORY
DATA
SD CARD READ/WRITE
WRITE
SD CARD READ/WRITE
READ
SCENE
WRITE
SCENE
READ
CAC FILE CARD READ
READ
CAC
CONTROL
CAC FILE CARD READ
DELETE
CAC ADJ
CAC FILE DELETE
Menu operations
To revise the set
value
SD memory card
SET UP data
No. of files: 8
It is possible to write eight
setup files on the SD
memory card.
CURRENT data
(Operating status of the unit)
No. of files: 1
USER data
No. of files: 1
FACTORY data
(Revision disable)
No. of files: 1
: Files built in the unit
: Menu operations
SCENE file
No. of files: 4
LENS file
No. of files: 8
SD memory card
Lens file
No. of files: 8
a
8
It is possible to write eight
titles for eight lens files on the
SD memory card.
CAC file
No. of files: 32
SD memory card