Wave Initialize
View all Yamaha SY85 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 248 highlights
WAVE INITIALIZE [SHIFT]+[UTILITY] → [SEQ SETUP] This function erases and initializes all wave memory, the specified type of wave memory, or a single specified sample. WAVE`Initialize`````Wave`Mem`Allocation` `Volatile`Mem.````````NonÒvol.``Mem`=off F1 F2 F3 F4 F5 F6 F7 F8 CS1 CS2 CS3 CS4 CS5 CS6 CS7 CS8 Mem (Memory type) Range: Volatile, Non-vol., all Controls: [CS2], [-1] [+1], Dial Use [CS2] to select either the volatile wave memory ("Volatile Mem."), non-volatile wave memory (Non-vol. Mem."), or all wave memory to be cleared. See "Wave Memory Expansion" on page 285 for additional information. Wave Mem Allocation Range: 0 ... 63, off Controls: [CS8], [-1] [+1], Dial All numbers from the number specified here to 63 are allocated for use as non-volatile waveform and sample numbers. Press [ENTER/YES] to begin the wave initialize procedure. The following confirmation display will appear: WAVE`Initialize`````Wave``Are`you`sure`? `Volatile`Mem.````````NonÒvol.``Mem`=off Press [ENTER/YES] again to confirm that you want to go ahead with the initialize operation, or press [EXIT/NO] to cancel. When the specified wave memory has been initialized, "Completed!" will appear briefly on the display. WAVE EDIT MODE / INITIALIZE 247