V Output through Door, 5V-2D OFF Signal
View all Brother International HL-2600CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
(3) Connector Pin Assignment ACN1 Manufacture: MoLex Type: 53313-2815 Pin No Signal Name Interface Pin No 1 +5V-1 +5V-1 Output 2 3 +5V-1 +5V-1 Output 4 5 +5V-D +5V-D Output 6 7 +5V-D +5V-D Output 8 9 ACSYNC-N AC Zero-Cross Signal (Open Collector Output). 10 11 +24V +24V Output connesponding to 12 Door Switch. 13 +5V-1R +5V through the relay when +24V-1 is shut down. 14 15 HON-N Heater On Signal (Pull-up required). 16 17 +24V-1 +24V Output through Door Switch. 18 19 +24V-1 +24V Output through Door Switch. 20 21 +24V-1 +24V Output through Door Switch. 22 23 +24V-1 +24V Output through Door Switch. 24 25 PGND Power Ground (+24V type ground) 26 27 PGND Power Ground (+24V type ground) 28 Signal Name DCOFF2-P SGND SGND SGND SGND DCOFF1-P ACOFF-P TestI2 TestO2 TestI1 TestO1 PGND PGND PGND Interface +5V-2D OFF Signal Signal Ground (+5V type ground) Signal Ground (+5V type ground) Signal Ground (+5V type ground) Signal Ground (+5V type ground) OFF Signal (Pull-up required) AC Forced Shut-Down Signal (Pull-Up required). Terminal for Dielectric Strength Test. Terminal for Dielectric Strength Test. Terminal for Dielectric Strength Test. Terminal for Dielectric Strength Test. Power Ground (+24V type ground) Power Ground (+24V type ground) Power Ground (+24V type ground) ACN1 Manufacture: MoLex Type: 53324-0710 Pin No Signal Name Interface Pin No 1 +5V-1 +5V-1 Output 2 3 SGND Signal Ground (+5V type ground) 4 5 +24V-2 +24V-2 Output 6 7 PGND Power Ground (+24V type ground) Signal Name +5V-D +24V-2 PGND Interface +5V-D Output +24V-2 Output Power Ground (+24V type ground) IV-58