Brother International HL-2600CN Service Manual - Page 314
Is ECN1 of IOD2 properly connected with 12CN of MCTL PWB 2
![]() |
View all Brother International HL-2600CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 314 highlights
Error Code Concerned Part E5 TR Cam Clutch 3 (TRCM) Confirm the connection of a TR cam clutch 3 connector. YES NO Is ECN8 of IOD2 properly connected with a connector of the solenoid ? Connect them properly. Is ECN1 of IOD2 properly connected with 12CN of MCTL PWB 2? YES Check the voltage(TRSLON-N/P) NO Is E5 error cleared ? YES Is a single voltage between ECN8-4 and ECN2-5 of IOD2 to be a trailing edge ? YES NO Is a single voltage between 5 of ECN2 and 18 of IOD2 to be a rising edge ? YES Replace TR cam clutch 3. Replace the IOD2 PWB 2. Job is complete. NO Is E5 error cleared ? YES Job is complete. NO Replace the MCTL PWB 2. MCTL IOD2 12CN ECN1 18 TRSLON-P 18 ECN8 TR Cam Clutch 3 1 +24V-1 4 TRSLON-N TRCM ECN2 +24V-1 1 PGND 5
![](/manual_guide/products/brother-international-hl2600cn-service-manual-a175c80/314.png)
Error Code
Concerned Part
TR Cam Clutch 3 (TRCM)
E5
Confirm the connection of a TR cam clutch 3 connector.
Is ECN8 of IOD2 properly connected with a connector of the solenoid ?
Is ECN1 of IOD2 properly connected with 12CN of MCTL PWB 2?
Check the voltage(TRSLON-N/P)
Is a single voltage between ECN8-4 and ECN2-5 of IOD2 to be a trailing edge ?
Is a single voltage between 5 of ECN2 and 18 of IOD2 to be a rising edge ?
Is E5 error cleared ?
Job is complete.
Is E5 error cleared ?
Connect them properly.
Replace the MCTL PWB 2.
Job is complete.
MCTL
12CN
18
ECN1
IOD2
TRCM
18
YES
YES
YES
NO
YES
NO
NO
TRSLON-P
PGND
YES
Replace TR cam clutch 3.
Replace the IOD2 PWB 2.
ECN2
1
4
ECN8
TRSLON-N
+24V-1
YES
NO
NO
+24V-1
1
5
TR Cam Clutch 3