the earthing harness., frame two hooks at bottom.
![]() |
View all Brother International HL-2600CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 255 highlights
3) Pull the SW unit upwards to remove it from the frame. 4) Remove the set screw M4X6 (1 pc.) complete with the shakeproof washer to release the earthing harness. 5) Remove the set screws ST3X6 (4 pcs.) to remove the power supply unit from the frame (two hooks at bottom). Hook Power supply unit Hook Fig.7-61 SW button SW unit WARNING The earthing wire is very important for the safety of users. Upon replacement of the power supply unit, confirm that the earthing wire (green and yellow color) is securely connected to the connector. VII-44
![](/manual_guide/products/brother-international-hl2600cn-service-manual-a175c80/255.png)
VII-44
3)
Pull the SW unit upwards to remove it from the frame.
4)
Remove the set screw M4X6 (1 pc.) complete with the shakeproof washer to release
the earthing harness.
5)
Remove the set screws ST3X6 (4 pcs.) to remove the power supply unit from the
frame (two hooks at bottom).
Fig.7-61
WARNING
The earthing wire is very important for the safety of users.
Upon replacement of the power supply unit, confirm that the earthing wire (green and
yellow color) is securely connected to the
connector.