When removing the fusing unit, take care to keep the unit level so that no oil leakage or spillage occurs. When shipping the printer, remove the oil bottle and the fuser cleaner from the fusing unit. After removing the oil bottle, be sure to remove the oil remaining in the fusing unit following the procedure below. Failure to do so will cause severe damage to the printer. i) Absorb the oil with the supplied syringe. ii) After absorbing the oil, stuff the soft paper into the oil pan so that no oil leakage occurs. Fig.6-20 Sequence of Replacement 1) Prepare a new fusing unit before starting the replacement work. 2) Return the roller tension release levers at both sides to the direction of the arrows. 3) Install the oil bottle and fuser cleaner onto the new fusing unit. Oil bottle Fuser cleaner Fig.6-21 VI-25