Brother International HL-2600CN Service Manual - Page 360
Fusing Unit, each of them into the polyethylene
![]() |
View all Brother International HL-2600CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 360 highlights
6.3 Fusing Unit 1) Open the rear access cover and slacken the fusing unit securing screws (2 pcs.) 2) Holding the handles at both ends of the fusing unit and remove the fusing unit from the printer. Fusing unit 3) Remove the oil bottle and the fuser cleaner from the fusing unit and put each of them into the polyethylene bag. Oil bottle Pack the oil bottle in the polyethylene bag and seal it firmly. Failure to do so will cause oil spill during shipping and damage to the printer. Fuser cleaner 4) Put the oil bottle and the fuser cleaner into the original starter kit packing. Oil bottle Starter kit packing Fuser cleaner 5) Remove the oil remaining in the fusing unit with the supplied syringe to avoid oil spill in the printer. Note: Re-install the fusing unit into the printer after cleaning the printer as instructed in the following section. For re-install of the fusing unit, see Section 6.6 'Packing'. A-14